RESOURCE A



                                                    TABLE 3.4—continued
                           FLOOR/CEILING ASSEMBLIES—HOLLOW CLAY TILE WITH REINFORCED CONCRETE
            ITEM   ASSEMBLY                                   PERFORMANCE       REFERENCE NUMBER           REC.
           CODE    THICKNESS        CONSTRUCTION DETAILS       LOAD  TIME  PRE-BMS-92 BMS-92 POST-BMS-92  NOTES  HOURS
                                      1
                           Floor cover: 1 / ″ gravel  cement (4300 psi);
                                       2        1
                                                 2
         F/C-HT-6     8″   three cell, 12″ × 12″ × 6″ ; 3 / ″ space between   165   4 hrs.          7  1, 3, 9,  4
                                          1
                           tiles including two  / ″ rebars with  1″ cover   psf                       10
                                           2
                                            1
                           from concrete bottom;  / ″ plaster cover, lower.
                                             2
                           Deck:  / ″ T&G on 2″  × 1 / ″ bottoms
                                7
                                              1
                                 8             2
                                    1
                           (18″ o.c.) 1 / ″ concrete cover (4600 psi); three
                                     2                               2 hrs.                          4, 11,
                                                                                                            1
         F/C-HT-7  9″ (nom.) cell hollow clay tiles, 12″ × 12″ × 4″; 3″ con- 95 psf           7            2 / 3
                           crete between tiles including one  / ″ rebar  / ″  26 min.                12, 13
                                                    3
                                                           3
                                                     4      4
                                        3
                           from tile bottom;  / ″ plaster cover.
                                         4
                           Deck:  / ″ T&G on 2″  × 1 / ″ bottoms (18″
                                                1
                                 7
                                  8              2
                                1
                           o.c.) 1 / ″ concrete cover (3850 psi); three cell
                                 2
                           hollow clay tiles, 12″ × 12″ × 4″;        3 hrs.                          4, 11,
         F/C-HT-8  9″ (nom.)                                  95 psf                          7
                           3″ concrete between tiles including      28 min.                          12, 13
                           one  / ″ rebar  / ″ from tile bottoms;
                                     3
                               3
                                4     4
                           1 / ″ plaster cover.
                             2
                           Deck:  / ″ T&G on 2″  × 1 / ″ bottoms (18″
                                                1
                                 7
                                  8              2
                                1
                           o.c.) 1 / ″ concrete cover (4200 psi); three cell
                                 2
                           hollow clay tiles, 12″ × 12″ × 4″;        2 hrs.                         3, 5, 8,
         F/C-HT-9  9″ (nom.)                                  95 psf                          7
                           3″ concrete between tiles including      14 min.                           11
                           one  / ″ rebar  / ″ from tile bottoms;
                                     3
                               3
                                4     4
                           1 / ″ plaster cover.
                             2
                                                               See
                                               1
                      1
                                                2
         F/C-HT-10   5 / ″  Fire clay tile (4″ thick); 1 / ″ concrete cover;   Note   1 hr.          43  15  1
                       2   for general details, see Note 15.
                                                                14
                                                               See
         F/C-HT-11    8″   Fire clay tile (6″ thick); 2″ cover.   Note   1 hr.                43      15    1
                                                                14
                           Fire clay tile (4″ thick); 1 / ″ cover;    See  1 hr.
                                              1
                      1
                                                                                                            1
         F/C-HT-12   5 / ″                     2               Note                           43      15   1 /
                       2   5 / ″ gypsum plaster, lower.         14  30 min.                                  2
                             8
                           Fire clay tile (6″ thick); 2″ cover;   See
                                                                                                            1
         F/C-HT-13    8″                                       Note   2 hrs.                  43      15   1 /
                           5                                                                                 2
                            / ″ gypsum plaster, lower.          14
                             8
                                                                                       2
         For SI: 1 inch = 25.4 mm, 1 foot = 305 mm, 1 pound per square inch = 0.00689 MPa, 1 pound per square foot = 47.9 N/m .
         Notes:
           1. A generalized cross section of this floor type follows:
           2. Failure mode - structural.
           3. Plaster: base coat—lime-cement-sand; top coat—gypsum (neat).
                                                        (continued)