Page 4 - ABB Indoor Apparatus Portfolio_Multimediale FlipBook_Neat
P. 4
4 SAFE AND RELIABLE DISTRIBUTION NETWORK ABB PORTFOLIO FOR MEDIUM-VOLTAGE INDOOR APPLICATIONS
—
ABB portfolio for medium-voltage indoor applications
Shaping a strong and reliable distribution network
Click on the product
names to know more.
Main function Vacuum Embedded Poles Circuit Breakers / Circuit Breakers / Circuit Breakers / Circuit Breakers/ Generator Circuit Contactors Enclosures & Kits Air Insulated Switch Gas Insulated Switch Indoor & Outdoor Circuit Breaker + Switching of dedicated
Interrupters IEC indoor ANSI indoor AC rail transport DC rail transport Breakers Disconnector Disconnector Fuses Switch application
Type VS#; VG# PT#; P#; OP# VD4; VM1; HD4 ADVAC®; AMVAC FSKII; FSG; GSx Gerapid; DCBreak VD4G; ADVAC®G ConVac PB family; Advance; NAL/F; VersaRupter GSec CEF; CMF; CLC; CIL; CXP; HySec VD4-AF; VD4-AF1; VD4-CS
L-Frame COL; CXLP
Applicable - - IEC (GB; GOST) ANSI IEC; ANSI; GB; GOST EN; IEC; ANSI IEC; ANSI IEC; GB (all versions); UL IEC; ANSI IEC; ANSI; GOST; CSA CSA IEC; GB IEC; ANSI IEC IEC 62271-100
Standard CSA (7.2 kV freestanding)
Maximum Rated 40.5 kV 46 kV 46 kV 38 kV 27.5 kV 800 V to 3600 V DC 15 kV 12 kV 38/40.5 kV 36/38 kV 24 kV 40.5 kV 24 kV 38 kV
Voltage
Maximum Rated 4000 A 4000 A 4000 A 4000 A 2500 A 1500 A to 8000 A 4000 A 400 A 4000 A 1250 A 800 A 315 A 630 A 2500 A (VD4-AF/VD4-AF1)
Current – 1250 A (VD4-CS)
Maximum Icc 63 kA 50 kA 63 kA 63 kA 31.5 kA 30 kA to 200 kA 63kA 6 kA 50 kA 31.5 kA 25 kA 63 kA (Breaking) 21 kA 32 kA
Applications Providing reliable elec- Key component contain- Primary and secondary Primary distribution Vacuum CBs designed to High speed DC circuit Generation protection Suitable for operating in Preassembled units Line switch disconnectors Three-position gas insu- Protection of distribution Multifunction apparatus Steel furnace (VD4-AF/
trical interruption tech- ing vacuum interrupter distribution protection, protection, CBs from cover single- and dou- breakers designed for and control (generators, alternating current, nor- designed to house ABB with or without fuses for: lated switch disconnector transformers, motors, ca- including CB, line discon- VD4-AF1), Reactive power
nology for: technology for: CBs from ABB are avail- ABB are available for ble-phase use in high energy, high transformers), CBs from mally used to control loads apparatus and suitable to cable sectionalizer and for: secondary distribution pacitor banks against over- nector and earthing switch compensation (VD4-CS).
Indoor/Outdoor circuit Indoor/Outdoor CBs, able for original equip- OEM to incorporate in applications for the rail- reliability DC power dis- ABB are available for requiring a high number of develop arc-proof switch- transformer switch; switchgear; feeders, trans- load currents. suitable for secondary
breakers (CBs) & Contactors, Reclosers. ment manufacturers their own installations way power supply and ap- tribution systems and OEM to incorporate in operations or to be gear and to design switch- motor switch (with motor former protection and ring Back-up, general purpose distribution switchgear.
switches, contactors, (OEM) to incorporate in or for use in repair, ret- plying a combination of a for rolling stock applica- their own installations or switched frequently. gear retrofits or upgrades. fuse CMF); switching of networks. and full range fuses.
switch disconnectors, their own installations rofit and upgrade proj- maintenance-free vacuum tion. for use in repair, retrofit capacitor banks. Incoming/outgoing panels Suitable for voltage
ring main units. or for use in repair, ret- ects. interrupter, magnetic ac- and upgrade projects. Local manufactured with CBs or in combination transformers, contactors,
rofit and upgrade proj- tuator and electronic con- panels. with fuses. compact switchgear and
ects. troller. Switch cubicles. Compact ring main units.
substation (kiosk).
Utility and industrial
application.
Technology Vacuum interruption Vacuum with solid di- Vacuum or gas interrup- Vacuum interruption / Vacuum interruption / Arc interrupted in air. Vacuum interruption / Vacuum interruption - - - - Vacuum interruption /Gas Servomotor actuation/
electric insulation tion / Solid dielectric in- Solid dielectric insula- Magnetic mechanism Arc chute design based Spring mechanism with monostable insulation/Airplus insula- Controlled switching /
sulation / Front or lat- tion / Front lineup / on cold cathode split- electromagnetic tion New vacuum interrupter
eral lineup / Spring or Spring or magnetic ting plate technology. actuation technology
magnetic mechanism mechanism Instantenous closing
and opening w/o chargi-
ning mechanism.
Main features Compact and robust High dielectric strength The world’s most suc- The ANSI most success- The GSx family (GSH II and Single pole DC circuit The world’s most Monostable Compact dimensions. Modular principle for wide Three-position SF6-insu- Unified voltage ratings for • Safe: mechanical New vacuum interrupter
design. without any further ex- cessful range of MV ful range of MV vacuum GSR II) includes a suitable breakers for use in trac- compact MV vacuum electromagnetic actuator. Limited weight. range of functionality. lated switch-disconnector more application. Flexibil- interlocks, circuit technology and innovative
Reliability and long life ternal precautions. vacuum and SF6 gas CBs. range of tion substations, at roll- generator CB. Available with electrical or With or without earthing Safe switching combina- (Line-Open-Earth). Metallic ity, Integrated striker pin breaker-line, actuation systems up to
from state-of-the-art Optimum protection of CBs. Full engineering and vacuum CBs designed ing stock vehicles and in Full engineering and mechanical latching. switch with making tion between disconnector Partition − Interlocks to with temperature control disconnector-earthing 38 kV, 2500 A/1250 A,
manufacturing the vacuum interrupter Full engineering and technical support. to cover single and other DC applications technical support. Compact dimensions. capacity. and current limiting fuse. prevent incorrect opera- unit to prevent overheating switch-panel door. 31.5 kA.
processes. from moisture, dust and technical support. Proven reputation for double-phase applica- that require highest per- Type tested in accor- Specific VIs for motor Upgrade obsolete switch- Dual arc extinguishing sys- tion. in installation place. • Long lasting: 10.000 Superior noise-free per-
Silicone moulding for external damage. Proven reputation for reliability, performance tions for the railway formance, up to 3600 V dance to the specific, switching. gear to new standards. tem, ensuring efficient Separate operating seats Overload spots control CO operations. formances.
maximum external Suitable for all conceiv- reliability, performance and long life. power supply. DC. High speed opening global dual logo IEC/ Up to 2,000,000 opera- Availability of interlocks. load current interruption. for isolation and earthing internal arc initiation and • Simple: CB, isolator Embedded advanced diag-
dielectric strength. able climatic conditions and long life. Products tailored for characteristics limiting IEEE standard. tions. With or without cable Unique design enables high operations. determine outstanding and interlock nostics.
Most frequently used and site altitudes. Products tailored for local markets. fault current. Fire proof Proven reputation for Fixed and withdrawable compartment. switching capacity. Applicable in combination temperature performance. functions in one single Higher performance than
switching technology Easy assembly on CBs. local markets. Short lead times. insulation materials are reliability, performance versions. Cassette type or floor Highest electrical perfor- with fuses and CBs. Graved fuse data for long apparatus. the market standard with
worldwide for medium Maintenance-free. Short lead times. Vacuum interrupters non toxic and are RoHS and long life. Plug and play accessories rolling. mance in the market. Wide range of ”plug and term fuse recognition. • Compact: fitting 150,000/10,000 mainte-
voltage. Efficient increase in di- Vacuum interrupters embedded or assem- compliant. Cadmium- Products tailored for for an easy customization. CSA and UL listed. play” accessories. Low power losses & high panels wide 500 mm nance-free operations.
Eco-efficient and main- electric strength with- (VIs) embedded or as- bled in the poles. free contact system, as- local markets. Compactness: only 375mm current limitation extends C2 class for capacitive Elimination of inrush limit-
tenance-free. out use of greenhouse sembled in the poles. Embedded poles pro- bestos-free arc chutes Short lead times. wide. insulation life time. switching. ing reactors and resis-
Proven with over 7 gases. Embedded poles pro- tect interrupter from and halogen-free ca- Fast response. Maintenance-free with High energy capability tances, leading to signifi-
million products in tect interrupter from impacts, dust deposits bling make breakers non Vacuum interrupters sealed for life technology. individual capacitor fuse. cant cost and space
service. impacts, dust deposits and humidity. toxic, safe for personnel embedded or assembled Up to 5,000 close-open savings.
and humidity. and have low impact on in the poles. operations.
enviroment. Embedded Integrated capacitive
control circuits provide dividers for voltage pres-
easy integration with ence indicator system.
panels and enclosures.
Quick inspection and
servicing with minimum
spare parts required.
Applications Vacuum Embedded Poles Circuit Breakers / Circuit Breakers / Circuit Breakers / Circuit Breakers / Generator Circuit Contactors Enclosures & Kits Air Insulated Switch Gas Insulated Switch Indoor & Outdoor Circuit Breaker + Indoor Disconnectors
Interrupters IEC indoor ANSI indoor Railways AC and DC Railways CB Breakers Disconnector Disconnector Fuses Switch & Earthing Switches
Primary Distribution Panel Builders • • • • • • • •
Secondary Distribution Panel builders • • • • • • • •
CSS manufacturers • • • • • •
MECB • • • • • •
Motors manufacturers • • • • •
Power transformers • • • • •
Distribution transformers • • • • •
MV Apparatus (CBs, Contactors, etc) • • •
Capacitors • • • • •
Generators • • • • •
Traction power susbtations •
Rolling stock vehicles •
Power converters •