Page 7 - ABB Indoor Apparatus Portfolio_Multimediale FlipBook_Neat
P. 7

9






















                                            VD4-AF
                                            Medium-voltage circuit breaker based on servomotors actuators.
                                            •  Reduced operation cost up to 50%
                                            •  Reduced maintenance burden and tied-up investment by 30%
                                            •  Increased circuit breaker performances level, 5-10 times compared to
                                              standard solution
                                            •  Designed for steel furnace application
                                            •  Rated up to 38 kV, 2500 A, 150,000 maintenance-free operations
                                            •  Embedded advanced diagnostics










          VD4-AF1

          New vacuum circuit breaker with servomotor actuation and controlled switching
          technology.
          •  Enables increased lifespan of transformers by more than 10% in e.g. 3 years
          •  Reduction of hazards due to improved protection range
          •  Up to 5-to-10-times higher endurance performance than the market standard
          •  Eliminated compensation losses up to 10% to increase power quality
          •  Cost saving by as much as 20%
          •  Designed for transformers protection
          •  Rated up to 38 kV, 2500 A, 31.5 kA and up to 150,000 operations with extremely low
           inrush
          •  Elimination of inrush limiting reactors and resistances, leading to significant cost
           and space savings








                                            VD4-CS

                                            VD4-CS is the unique solution based on new vacuum interrupter technology
                                            to support reactive power compensation applications.
                                            •  Up to 5-times higher performance than the market standard with 10,000
                                              operations
                                            •  Cost saving by as much as 20%
                                            •  Enables increased lifespan of capacitors by more than 10% in e.g. 3 yrs
                                              thanks to predictive health indication
                                            •  Designed for capacitor banks
                                            •  Rated up to 38 kV, 1250 A, 31.5 kA, 10,000 maintenance-free operations
                                            •  Noise-free operations
                                            •  Embedded advanced diagnostics
   2   3   4   5   6   7   8   9   10   11   12