COATING REMOVAL & MAINTENANCE 130
COATING REMOVAL
Application Rotation Speed
Ceramic tile adhesive removal 800-1500rpm
Carpet glue removal 800-1500rpm
Epoxy paint removal 1200-1500rpm
Rain damaged concrete 1200-1500rpm
Smoothen exposed aggregate 1200-1500rpm
Lippage removal in terazzo/stone tiles 800-1200rpm
Concrete polishing with metal bonded tools 16-80 grits 800-1200rpm
Grouting procedure during shinningflat process 300-500rpm
50-100 resin pads 1250-1950rpm
400-800 resin pads 1500-1950rpm
MACHINE STANDARD WIRE SIZE
Maintenance Tips
1. Make sure three active lines and the earth line is well connected when machine is 380V or 220V three phase.
2. Earth line must be connected for safety ( do not mix the earth line and neutral) and assemble a breaker at
the panel.
3. Never do the wiring when power is on.
4. Check the quality of cables before wiring, no broken insulating layer or short-circult.
5. There should be no loosen on cable terminals after wiring and make sure the same as machine motor voltage.
Check the power leakage protection device to prevent any risk.
Motor Power Voltage Wire Size
2.2kW/3kW 1P 220V 3x2.5mm2
1P 220V 3x4mm2
4kW
3P 220V/380V 3x2.5mm2 + 1x1.5mm2
1P 220V 3x6mm2
5.5kW
3P 220V/380V 3x4mm2 + 1x2.5mm2
1P 220V 3x6mm2
7.5kW 3P 220V 3x6mm2 + 1x4mm2
3P 380V 3x4mm2 + 1x2.5mm2
1P 220V 3x10mm2
11kW 3P 220V 3x10mm2 + 1x6mm2
3P 380V 3x6mm2 + 1x4mm2
3P 220V 3x10mm2 + 1x6mm2
15kW
3P 380V 3x10mm2 + 1x6mm2
The recommended wire size listed above are for length within 50 meters. If the length is more than 50
meters, the size should be one grade thicker. Like original is 2.5mm2 , now should be one grade thicker.