    COATING REMOVAL
    Application                 Rotation Speed
    Ceramic tile adhesive removal  800-1500rpm
    Carpet glue removal         800-1500rpm
    Epoxy paint removal         1200-1500rpm
    Rain damaged concrete       1200-1500rpm
    Smoothen exposed aggregate  1200-1500rpm
    Lippage removal in terazzo/stone tiles  800-1200rpm
    Concrete polishing with metal bonded tools 16-80 grits  800-1200rpm
    Grouting procedure during shinningflat process  300-500rpm
    50-100 resin pads           1250-1950rpm
    400-800 resin pads          1500-1950rpm
    MACHINE STANDARD WIRE SIZE
    Maintenance Tips
    1. Make sure three active lines and the earth line is well connected when machine is 380V or 220V three phase.
    2. Earth line must be connected for safety ( do not mix the earth line and neutral) and assemble a breaker at
        the panel.
    3. Never do the wiring when power is on.
    4. Check the quality of cables before wiring, no broken insulating layer or short-circult.
    5. There should be no loosen on cable terminals after wiring and make sure the same as machine motor voltage.
        Check the power leakage protection device to prevent any risk.
       Motor Power  Voltage     Wire Size
       2.2kW/3kW    1P 220V     3x2.5mm2
                    1P 220V     3x4mm2
        4kW
                   3P 220V/380V  3x2.5mm2 + 1x1.5mm2
                    1P 220V      3x6mm2
        5.5kW
                   3P 220V/380V  3x4mm2 + 1x2.5mm2
                    1P 220V      3x6mm2
        7.5kW       3P 220V   3x6mm2 + 1x4mm2
                    3P 380V   3x4mm2 + 1x2.5mm2
                    1P 220V     3x10mm2
        11kW        3P 220V   3x10mm2 + 1x6mm2
                    3P 380V    3x6mm2 + 1x4mm2
                    3P 220V   3x10mm2 + 1x6mm2
        15kW
                    3P 380V   3x10mm2 + 1x6mm2
    The recommended wire size listed above are for length within 50 meters. If the length is more than 50
    meters, the size should be one grade thicker. Like original is 2.5mm2 , now should be one grade thicker.