Page 591 - Chief Architect Reference Manual
P. 591

Window Specification Dialog



                               •  An additional Right Inside Corner can be
                                  specified in a similar manner.        Note:  The  Left  and  Right  settings  on  this
                                                                        panel refer to the window’s exterior.
                                4   The Bottom Corners settings allow
                                    you to raise the heights of the bottom   The following diagram represents added
                               corners, as measured from the bottom of the   Inner corners using open circles and the left
                               window specified on the General Panel.  and right corners using solid black circles:
                               •  Check Left to raise the height of the bot-
                                  tom left corner.
                               •  Specify the Height of the bottom left cor-
                                  ner. This value cannot exceed the Height
                                  of the Left Side.








                                                                       •  A has different left and right Side Heights
                                                                          with no Top Inside Corner added.
                               •  The height of the Bottom Right corner   •  B has matching left and right heights with
                                  can be raised in a similar manner.      an added Top Inside Corner.

                                5   A preview of the selected window   •  C is the same as B, except that the left
                                    displays here. You may want to rotate   and right Side Heights have been short-
                               the view so the window’s exterior can be   ened to 1/4”.
                               seen. See “Dialog Preview Panes” on page   •  D is the same as B except it has two
                               42.
                                                                          added Top Inside Corners.
                                                                       •  E is the same as A except that the Bottom
                                                                          Right Corner has been raised.

                                                               Arch Panel
                               The settings on ARCH panel of the Mulled   constructed with horizontal, straight tops all
                               Unit Specification dialog define the overall   at the same height.
                               shape of the blocked unit’s top. If the mulled   The ARCH panel is not available for window
                               unit already includes a component window   symbols, and its settings are not available if
                               with an arch, these settings cannot be   the selected window has been modified using
                               modified. If you intend to arch the top of a   the Shape Panel.
                               mulled unit, the top components should be







                                                                                                       591
   586   587   588   589   590   591   592   593   594   595   596