Page 814 - Chief Architect Reference Manual
P. 814

Chief Architect X10 Reference Manual



                           pivot point. If the plane is drawn over a   • Clip End - This is the amount a ceiling
                           wall, this is located at the inside surface of   rafter’s underside must be clipped at its
                           the wall’s Main Layer.                 lower end to rest on the wall top plate, and
                        • Define the Outside Bottom Height, or    is zero if the ceiling plane was not drawn
                           lock this value to make it the ceiling   over a bearing wall. This value is equal to
                           plane’s pivot point. Only available when a   the ceiling plane’s rise in slope over the
                           ceiling plane is drawn over a wall, this is   distance of the Overhang from Inside
                           the height of the lower edge of the ceiling   Bottom.
                           rafters, were they not clipped by the wall
                           below.                                 The Outside Bottom value plus the Clip
                                                                  end value equals the Top of Plate value.
                        • Specify the selected ceiling plane’s Pitch,
                           or lock this value to move the plane verti-  3  In Chief Architect Interiors only,
                           cally when a Height value is changed.    specify how the Ceiling Finish surface
                                                                on the underside of the selected ceiling plane
                        • Check Pitch in Degrees to display the   is built. In Chief Architect Premier, the
                           Pitch value in degrees. See “Roof Pitches   Ceiling Finish is specified on the STRUCTURE
                           in Degrees” on page 833.
                                                                panel.
                         2  Measurements - Information about the   •When Use Room Ceiling Finish is
                            structure of the selected ceiling plane(s)   checked, the selected ceiling plane’s ceil-
                        displays here for reference.              ing finish thickness and material are
                        • The default Structure Thickness is the   defined by the room below and the “Ceil-
                           same as that for roof planes and is set in   ing Surface” component will not be avail-
                           the Build Framing dialog. See “Build   able on the MATERIALS panel. Uncheck
                           Framing Dialog” on page 844.           this box to define the ceiling finish as part
                        • The Vertical Structure Depth is defined   of the ceiling plane and enable the Ceil-
                           by measuring a plumb line through the   ing Thickness option.
                           ceiling structure. The greater the pitch,   • Specify the Ceiling Thickness, which is
                           the greater the vertical structure depth.  the thickness of the bottom surface of the
                        • The Top of Plate is the top plate height of   ceiling plane.
                           the bearing wall, and is also the ceiling   Check Curved Ceiling to specify the
                           height of the room.                   4  selected ceiling plane as curved. See
                        • Overhang From Inside Bottom - Only    “Curved Roof Planes” on page 808.
                           appearing when a ceiling plane is drawn   • Specify the ceiling plane’s Angle at
                           over a bearing wall, this is the horizontal   Eave, Angle at Ridge and Radius to
                           distance from the Baseline to the inside   Framing Bottom.
                           Main Layer surface of the wall. The Base-  • These three values are interrelated - when
                           line is typically drawn over the outside   one is changed, the other two adjust
                           Main Layer surface, so this value is equal   accordingly. You may find it helpful to
                           to the wall’s Main Layer thickness.




                   814
   809   810   811   812   813   814   815   816   817   818   819