Page 62 - CAT-SAFETOP-2019-ENGLISH
P. 62

¿When should we use a disposable mask?
               When the oxygen concentration is higher than 17%.
               I know to which pollutant I am exposed.
               The contaminant is olfactively detectable.

                Protection level              FFP1                  FFP2                     FFP3


                                          NON TOXIC DUSTS    FINE - TOXIC PARTICULATES     ULTRA FINE,
                                        Silicon, rock wool, graphite,  Sanding metallic parts,   TOXIC PARTICULATES
                                       cement, sulfur, coal, ferrous   resin, scum, etc.  lead, asbestos, ceramic fibres,
                                         metals, softwood, etc.                         blasting concrete, etc.
                                                                Against dusts, fumes
                                                                    or aerosols         gainst poisonous dusts,
                                                                                         fume and aerosols
                                      DIY AND OTHER PURPOSES    INFLUENZA VIRUSES      ASBESTOS, ALLERGIES,
                                         Cut and grind of wood,   tuberculosis, bird flu, A flu, etc.  VIRUSES, BACTERIA, FUNGI
                                       iron, Steel, crystal, textil, etc              Asbestos (concentration lower
                                                                                       than 1 fibre/cm in 1 hour)
                                                                                                 3
                                                                ASBESTOS FIBRES       Or Legionella (short duration)
                                                               Silicones, asbestos, lead,  Effective in case of pollen allergie
                                                               Steel/zinc fumes, Chrome
                                                                   sulfur and oils
                                                                                        CHEMICAL INDUSTRY
                                                                                    oncogenics, poisonous particulates,
                                                                                       berillyum, nickel, uranium
                                   Activated carbon
                   ACTIVATED
               C   CARBON          Models with activated carbon eliminate odors and discomfort caused by low levels of orga-
                                   nic vapors that are found next to the particles.

                                   Dolomite clogging
              D   DOLOMITE         The optional Dolomite obstruction test is intended to check the maintenance of the filtering
                  CLOGGING
                                   capacity when a certain amount of dolomite is passed through the filter, a very fine powder
                                   that clogs the pores and saturates the filtering surface. Masks that include the letter "D" are
                                   suitable for use against this type of powder. Ideal for exposure to wood dust.


                                   Exhalation valve
                                   The models with valve provide greater comfort, reduce moisture condensation inside, pre-
                                   vent fogging of glasses, offer a feeling of less resistance and help inspire-expire easily.

                                   Pre-formed
                                   When the user breathes in air, the valve closes the diaphragm; when it exhales, it opens.
                                   The valve releases air down to prevent condensation in the glasses. If the worker wears
                                   protective glasses, this helps to prevent them from being fogged up.

                                   Foldable: Horizontal or Vertical
                                   Very easy to keep and store
                                                                                FFP1NR    FFP2NR    FFP3NR
              Exhalation valves reduce the hot air inside and reduce  Inside filtration (TIL)  <22%  <8%  <2%
              the stress of breathing; they also facilitate breathing in
              humid and hot environments.              Penetration
              Activated carbon is used against annoying organic va-  Solid aerosols  S<20%  S<6%      S<1%
              pors.                                    Liquid aerosols           L<20%      L<6%      L<1%
              The contour is thermo-sealed, and the adjusting elastics  % of Carbon
              are either sealed to the mask, or fastened by quick fixa-  Dioxide content  <1%  <1%    <1%
              tion devices.
                                                       Inhalation resistance     <0,6%      <0,7%     <1%
              Depending on their shape, they are divided into: molded  30 l/min (mbar)      mb        mb mb
              or folded. The moldings always have a better facial adap-
              tation; the folding ones are individually packaged, they  Inhalation resistance  <2,1%  <2,4%  <3%
              can be easily stored while they are not used and they can  95 l/min (mbar)  mb  mb      mb
              be folded horizontally, with a wide interior cavity; and verti-  Inhalation resistance
              cal folding.
                                                       160 l/min (mbar)          <3 mb      <3mb      <3mb
              They have different classifications according to the nomi-  (controlled by PPE’s)
              nal factor of protection.

                      60