To determine the nozzle flow rate:
Time the seconds necessary to fill a pint container from a nozzle. Divide the number of seconds into 7.5.
gallons/minute/nozzle = 7.5 7.5 =3 gal./minute
seconds 2.5 sec.
To determine the acreage sprayed per hour:
acres sprayed/hour = boom width (ft.) x MPH x 5280 ft. 24 ft.x5MPHx5280 =14.5 acres
43,560 ft. 2 43,560
Sprayer Tank Capacity*
1. Cylindrical Tanks:
2
gallons = length x diameter x 0.0034 240x72x0.0034 =58.7 gallons
2. Elliptical Tanks:
gallons = length x short diameter x long diameter x 0.0034 240x24x36x0.0034 =705 gallons
3. Rectangular Tanks:
gallons = length x width x depth x 0.004329 240x36x48x0.004329 =1795 gallons
*Note: all tank measurements in inches
Proportionate Amounts of Dry Material
Water gallons Quantity of Material
100 1 lb 2 lb 3 lb 4 lb 5 lb
50 8 oz 1 lb 24 oz 2 lb 2½ lb
5 3 tbs 1½ oz 2½ oz 3¼ oz 4 oz
1 2 tsp 3 tsp 1½ tbs 2 tbs 3 tbs
Proportionate Amounts of Liquid Material
Water gallons Quantity of Material
100 1 qt 1 pt 1 cup
50 1 pt 1 cup ½ cup
5 3 tbs 5 tsp 2½ tsp
1 2 tsp 1 tsp ½ tsp
Miles per Hour (MPH) Converted to Feet per Minute (FPM)
MPH FPM
1 88
2 176
3 264
4 352
215