Page 40 - Tunnel Support Components
P. 40

TUNNEL SUPPORT COMPONENTS


             Installation


             Triple Foam Panel


                3-Way Valve
                                                                         Exhaust Port  Pressure feed to Gauges

                 Requires a 110VAC feed from DCC output board.
                                                           Main air supply
                                                                                          110VAC
                                                                                          Feed

                                                       Pressure Adjustment



                Chemical Pumps
                 The Pulsatron™ pump can be either Hyper
                 Concentrate or Super Concentrate.  It  has
                 two adjustment knobs located on the pump
                 face  and one priming bypass control                 Fluid output line

                 located on the base of the fluid output line.
                 Of  the  two  knobs on the face of the
                 chemical pump, the larger one  regulates      Priming                  Feed back
                                                                                        to chemical
                 the pumps stroke length, whereas the          Bypass                   drum
                 smaller knob alters the stroke rate (cycles
                 per second).
                                                                                        DO NOT ADJUST THIS
                 To prime the pump, fully open the bypass                               KNOB UNLESS THE
                 knob. This will shorten the fluid path and   Stroke Length             PUMP IS RUNNING
                 allow  the  chemical to loop directly back
                 into the chemical drum. Once the  pump                                 Stroke Rate
                 has been primed, close the bypass knob.   110VAC Feed

                 For  best  results, the drying agents and
                 sealer waxes should use 100% stroke rate.
                 To alter the chemical usage, adjust the
                 stroke length.

                                                                  Exhaust Port  Pressure feed to Gauges
                Pressure Regulator
                 Requires an 110VAC feed supplied by DCC.


                                                         Pressure Gauge

                                                       Pressure Adjustment