Page 147 - Saber® Installation & Startup
P. 147
INSTALLATION & STARTUP
Chapter 9 Water Softener
Bypass Valve System: Minimum 2” floor drain required. Inlet/Outlet header system should
remain the same size as the existing line(s).
Model 213S OD / WB
Non-softened water in Five field supplied Shutoff Valves
This line MUST be 2” @ 40PSI or or (normally open, close to bypass system)
less. It can be 1-1/2” @ 40PSI or Softened water
greater. The other lines are as follows:
out
· WB, 1-1/4” or 1-1/2” copper tubing.
One field supplied Shutoff Valve
(normally closed, open to
bypass system)
Model 213S OD / WA Three field supplied Shutoff
Valves (normally open,
Non-softened water in
close to bypass system)
These lines are to be 1-1/4” or 1-1/2”.
All copper tubing.
Softened water
out
One field supplied Shutoff Valve
(normally closed, open to
bypass system)
1MANUL290 Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681 9-3