Page 16 - The Chameleon® Stik
P. 16

THE CHAMELEON® STIK


             Installation


             Utility Connection: Flasher Unit not Desired

                    1)  Electrical conduits between electrical enclosures.
                    2)  All wires are #12AWG except the control wires to the relay.
                    3)  User must supply from existing electrical power panel, a supply source of 120VAC through a
                       20Amp dedicated breaker.



                                      No other connection from this breaker.

                    4)  User must supply a 120VAC signal from existing  car  wash control panel such as “Datatrax™”,
                       “Compuwash™” , MCC or CCU.
                    5)  Electrical connections at The Chameleon®  Stik are made using wire nuts and covered with
                       electrical tape.
                    6)  User supplied relay. Contacts must have a .2 AMP rating.


                                   Connections
                         Conduit Side       Chameleon®  Side

                           120VAC       to    Black L1
                           Neutral      to    White L2






































             12            Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681           1MANUL520