            The following is the factory default setting and a brief description of each field.

                FRICTION
                     Runs soap chemical pump during fill time, first 40 inches, and last 40 inches of carriage
                     travel. Operates city water valve during entire application.  Operates top, enter, and exit
                     wheels (back to front passes exclude top wheel).
                FRIC/RNS
                     Runs soap chemical pump only during last eleven inches. [This is done primarily to  fill
                     manifold on machine and not for dispensing soap onto wheels.] Operates rinse/wax water
                     valve for entire application. Operates city water valve during entire application. Operates
                     top, enter, and exit wheels (back to front passes exclude top wheel).

                OB DRYER
                     Operates dryer output during entire application.  Activates special features for on-board
                     dryer.  This includes concentrator output and spinning top wheel and dryer motors are
                     winding up to speed.
                SOAP
                     Operates both soap chemical pump output and soap water/air  output  during  entire
                     application. Operates city water valve during entire application. Front distance is  132
                     inches. This allows rapid speed for first 132 inches when front speed increased.
                SOAP/F-CTA
                     Operates both soap chemical pump output and soap water/air  output  during  entire
                     application. Operates city water valve during entire application. Operates CTA output from
                     position 22 to 40 regardless of direction machine is traveling. The intension of this pass is
                     to get some extra chemical and soak time on  the front rim. This is typically used in
                     conjunction with tire on-board CTA application that is package pass selectable.

                TRI-FOAM
                     Operates both triple foam pump output and triple foam water/air output during entire
                     application.  Operates city water valve during entire application.

                TRI-SOAP
                     Operates both triple foam pump output and triple foam water/air output during entire
                     application.  Operates city  water  valve  during entire application. Operates both soap
                     chemical output and soap water/air during entire application. Front distance is 132 inches.
                     This allows rapid speed for first 132 inches when front speed increased.
                DRY AGENT
                     Operates drying agent chemical pump output during entire application except last 4 inches
                     of carriage travel. Operates rinse/wax water output during entire application.  Operates city
                     water valve during entire application.