Page 10 - Photo Eye (Deluxe)
P. 10

PHOTO EYE (Deluxe)


            Installation


            General

                There are two types of mounts available. The floor mounted and the wall mounted. Both styles are
                wired the same but they have different variables to consider for positioning. DO NOT secure the
                Photo Eyes into place until you have read this entire section.


               Identification


















               Alignment
                   1)  Point the Emitter directly at the Receiver
                   2)  Point the Receiver directly at the Emitter
                   3)  Finely adjust the position of the Receiver until “Indicator 4” of the Signal Strength Light Bar is ON

                   Note:  If Indicator 4 of the Signal Strength Light Bar can NOT be obtained, try re-adjusting
                          the Emitter and repeat step 3.

               Working Temperature Range

                   •   Non-Heated: 33° to 130° Fahrenheit
                   •   Heated: -10° to 90° Fahrenheit

                   Note:  If optional heat package has been installed, turn the power to the heat OFF before the
                          temperature exceeds 90° Fahrenheit. Turn it back ON before the temperature falls below 33°
                          Fahrenheit.























              8            Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681             1MANUL580