Page 13 - Top Wheel Signature® Series
P. 13

SignatureSignature   SeriesSeries
                      TOP WHEEL SignatureSignature  ®      SeriesSeries

                      Specifications


                      Requirements

                          Physical
                             Tunnel space required    114”

                             Unit height             140”
                             Unit width              150-7/8”
                          Utility
                             Electrical              3 phase, 1HP motor
                                                     110V for Retract Option
                             Pneumatic               .3 CFM @ 90 PSI minimum 120 PSI maximum
                             Water                   (1) 3/4” hose @ 4 GPM @ 40 PSI


                      Output

                          Physical
                             Vehicle clearance, height    90”







                                DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE SERVICING ANY
                                                               EQUIPMENT!

                                                           CAUTION

                                     Always wear safety glasses when performing maintenance on any equipment

                                                           CAUTION

                             It is recommended that a licensed electrician is contracted to perform all electrical installations.

                                                           CAUTION

                              YOUR HYDRAULIC SYSTEM MUST BE CAPABLE OF ADJUSTMENT TO 116 RPM AT
                                900 PSI (62.1 BAR) WHILE LOADED AGAINST VEHICLE. PLEASE VERIFY YOUR
                               SYSTEMS CAPABILITY TO MEET THESE SETTING WHILE RUNNING A VEHICLE
                                               PRIOR TO INSTALLING PIECE OF EQUIPMENT

                                                           CAUTION

                                 A compressed Air System should be set correctly to support 90 PSI necessary to operate
                              equipment, but should never be set to deliver more than 120 PSI air pressure to the Belanger
                                                            specified equipment.





                       1MANUL752            Belanger, Inc. * 1001 Doheny Ct. * Northville, MI 48167 * Ph (248) 349-7010 * Fax (248) 380-9681        9