            Chapter 6 Sudzer® FM Maintenance


            Trouble Shooting

                    Problem                  Cause                            Solution
               Chemical Delivery:      Clogged foot valve on suction      Clean or replace foot valve
                    No chemical         line                      Fill storage tank
                                       Empty storage tank
                                                                  Prime chemical pump
                                       Chemical  pump  has  lost
                                        prime                     Check for proper operating voltage
                                       Solenoid valve not energized
               Chemical Delivery:          Nozzles clogged       Verify Spray Nozzles are pointing downward and
                   Pulsating or        Dirt in solenoid valve     toward the center finger of the Tri Nozzles
                    Weak Spray                                    Remove  Bayonet  Nozzle  from  Tri  Nozzle  and
                                       Kink in hose               clean with thin wire
                                       Inadequate water pressure
                                                                  Remove Bayonet Nozzle from Tri Nozzle, verify
                                                                   arrow  on  check  vavle  is  pointing  toward  the
                                                                   spray nozzle
                                                                  Disassemble Bayonet Nozzle clean components
                                                                   and reassemble with pipe dope
                                                                  Disassemble and clean solenoid valve
                                                                  Remove any kinks from hose
                                                                  Open water valve to fullest
                                                                  Call  Distributor  for  advice  on  installing  booster
                                                                   pump
               Wall Washers:           Incorrect wire connections      Check  electrical  connections  at  Wall  Washer
                   Not Turning On      Controller Program         and Air Plenum
                                                                  Verify  wire  connections  in  24vdc  Power  Pupply
                                                                   Enclosure
                                                                  Check Main power coming into the 24vdc Power
                                                                   Supply Enclosure
                                                                  Verify that the Controller has been programmed
                                                                   properly
               Wall Washers:           Controller Program        Verify that the Controller has been programmed
                   Not Turning Off                                 properly

               Wall Washers:           Not adjusted when installed      Manually rotate Wall Washers on Pivot Brackets
                   Incorrect Position                              to direct light onto bubbles and vehicle

               LED in Nozzles:         No power                  Check the wiring in the 24VDC Power Enclosure
                   Not Lit             Incorrect wire connections      Check  the  electrical  connections  betweent  the
                                                                   Main Power cable and Wire Harness
                                       Controller Program
                                                                  Check  to  make  sure  the  wire  connections  are
                                                                   correct betweent the Wire Harness and the LED
                                                                   Assembly in the Nozzle
                                                                  Verify that the Controller has been programmed
                                                                   properly
               LED in Nozzles:         Incorrect wire connections      Check  to  make  sure  the  wire  connections  are
                   Not Turning Off      Controller Program        correct in the 24VDC Power Enclosure
                                                                  Verify that the Controller has been programmed
                                                                   properly



             1MANUL026        Belanger, Inc.® * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681   6-2