Page 51 - Kondor® KL 2 - E-1063 Programming and Operation Manual
P. 51

®
                      KL2: 1063 PROGRAMMING AND OPERATION


                      Chapter 6 Faults and Alarms


                      Alarm Summaries

                          ARM RESISTANCE DETECTION
                               This alarm occurs when Final Arm Home was completed by the timer instead of the Home Prox.
                          CHECK THERMOSTAT
                               This alarm occurs when the heater output has been blocked from staying on because it has been on for longer
                               than 45 minutes.
                          CHECK ARM PROX
                               This alarm occurs when the arm is slowed down because its position remains at ZERO for too long after the
                               arm has started moving. The position will increase from ZERO with any change of input status from the Arm
                               Encoder Prox.

                          BREAKAWAY FROM JAM PREVENTION
                               This alarm occurs if the machine has gone into the Breakaway condition because a Butterfly Jam was about to
                               occur. This alarm occurs in order to verify if either arm is being jammed because it is pressed against a vehicle
                               but the arm did not break away. This “pseudo” break away can only occur once per vehicle.
                          EXCESSIVE POSITION CORRECTION
                               This alarm occurs when the Position Resets to ZERO at the Exit Limit but the Carriage Position Error at the
                               time of correction was 30 or greater.