            Window weatherstrip spring brass seal sets. Peel ‘N Stick®, per linear foot per side.
              Double-hung window, head and sill            BC@.008    LF      1.81       0.32       2.13
              Add to remove and replace window sash        BC@.250    Ea         --    10.07      10.07
              Casement window, head and sill               BC@.008    LF      0.94       0.32       1.26
              Gray or black pile gasket                    BC@.008    LF      0.71       0.32       1.03
              Gray or black pile gasket with adhesive      BC@.006    LF      1.04       0.24       1.28


            Specialty Windows and Skylights

            Window well, ScapeWEL. Meets code requirements for basement egress window. Snaps into place
            on-site. For new construction and remodeling, attaches directly to foundation. Two-tier. 41" projection
            from foundation. 48" high.
              42" wide window, 3' window buck               B1@1.50   Ea 1,060.50      54.68    1,115.18
              Polycarbonate well cover                       --@.000  Ea    474.70         --    474.70
              54" wide window, 4' window buck               B1@1.50   Ea 1,131.20      54.68    1,185.88
              Polycarbonate well cover                       --@.000  Ea    477.73         --    477.73
              66" wide window, 5' window buck               B1@1.50   Ea 1,151.40      54.68    1,206.08
              Polycarbonate well cover                       --@.000  Ea    530.25         --    530.25

            Tubular skylights with install kit. Acrylic dome on the roof reflects sunlight down a light shaft,
            providing natural light for bathrooms and hallways. Use a 10"-diameter tube for rooms to 150 square feet
            and a 14"-diameter tube for rooms to 300 square feet. Use the composition flashing kit for asphalt
            shingle, slate, or wood shake roofs. Aluminum flashing kit is suitable for other surfaces with pitch from
            level to 12 in 12. Adjustable tubes make it easy to maneuver around obstacles. Kit contains material to
            complete a 48" installation from roof surface to interior ceiling surface. Fits between 16" or 24" on center
            rafters.
              10" tube, aluminum flash kit                  B1@3.00   Ea    221.19    109.40     330.59
              10" tube, composition flash kit               B1@3.00   Ea    183.82    109.40     293.22
              10" tube, tile or flat roof                   B1@3.00   Ea    225.23    109.40     334.63
              14" tube, aluminum flash kit                  B1@3.00   Ea    333.30    109.40     442.70
              14" tube, composition flash kit               B1@3.00   Ea    277.75    109.40     387.15
              14" tube, tile or flat roof                   B1@3.00   Ea    337.34    109.40     446.74

            Remove an existing poly dome skylight. No salvage of materials. Includes disposal.
              To 10 square feet                             BL@2.65   Ea         --    86.44      86.44
              Add per square foot over 10 square feet       BL@.210   SF         --      6.85       6.85
              Remove and replace poly dome only             BL@1.00   SF     13.53     32.62      46.15

            Cut roof opening for a skylight. Cut shingles and sheathing, install L-flashing. Self-flashing
            flush-mount skylights can be installed directly on a roof with a pitch of 3 in 12 or greater. Curb-mounted
            skylights require a roof curb. Add the cost of roof framing (doubled rafters and two headers) if required.
            Add the cost of framing a light well through the attic, if required. Add the cost of cutting and finishing a
            hole in the ceiling (including doubled joists and two headers) if required.
              Measure and cut roof opening for skylight    BC@3.50    Ea         --   140.90     140.90
              Frame roof curb                              BC@2.00    Ea     24.64     80.52     105.16
              Curb flashing for skylight                   BC@1.25    Ea     97.47     50.33     147.80

            Fixed flush-mount skylights, Velux. Low-E insulating laminated and tempered glass. Wood interior
            frame. Exterior aluminum cladding covers gaskets and sealants. Pre-mounted brackets allows
            adjustment for high or low profile roofing materials
              15-5/16" x 46-3/8"                            B1@3.42   Ea    248.46    124.70     373.16
              21-1/2" x 27-1/2"                             B1@3.42   Ea    204.02    124.70     328.72
              21-1/2" x 38-1/2"                             B1@3.42   Ea    254.52    124.70     379.22
              21-1/2" x 46-3/8"                             B1@3.42   Ea    284.82    124.70     409.52
              30-5/8" x 38-1/2", Type 74                    B1@3.42   Ea    305.02    124.70     429.72
              30-5/8" x 38-1/2", Type 75                    B1@3.42   Ea    257.55    124.70     382.25