Page 313 - 2018 National Home Improvement
P. 313

2018 National Home Improvement Estimator, All Rights Reserved                                   Page 254



              Add for job setup, per room                  BC@.150    Ea         --      6.04       6.04
              Staple tile to 1" x 2" furring strips, including strips,
               per square foot of tile                     BC@.042    SF         --      1.69       1.69
              Add for job setup, per room                  BC@.150    Ea         --      6.04       6.04
              Set tile directly on ceiling with adhesive, including
               cove molding, per square foot of tile       BC@.020    SF         --      0.81       0.81
              Add for job setup, per room                  BC@.150    Ea         --      6.04       6.04
              Secure loose tile by nailing or driving screws,
               per tile                                    BC@.035    Ea         --      1.41       1.41

            Ceiling tile. Covers cracked or stained drywall ceilings. Fire-retardant. Stapled or set with adhesive.
              24" x 24", Good                              BC@.020    Ea      1.77       0.81       2.57
              24" x 24", Better                            BC@.020    Ea      2.63       0.81       3.43
              24" x 24", Best                              BC@.020    Ea      5.05       0.81       5.86

            Tin design ceiling tile. Hidden seams, durable, vinyl-coated, fire-retardant.
              12" x 12"                                    BC@.020    Ea     16.16       0.81     16.97

            Wood fiber ceiling tile. Class C panels for non-acoustical and non fire-rated applications.
            Tongue-and-groove edging hides staples for a smooth, clean look. 12" x 12" x 1/2" with staple flange.
            Stapled or set with adhesive.
              Lace                                         BC@.020    Ea      0.95       0.81       1.75
              Tivoli                                       BC@.020    Ea      1.07       0.81       1.88
              White wood fiber                             BC@.020    Ea      0.98       0.81       1.78

            Acoustical ceiling tile adhesive, 237, Henry. For use on 12" x 12" or 12" x 24" tile. Bonds to
            concrete, concrete block, drywall, plaster and brick. 30-minute working time. One gallon covers 60
            square feet.
              Per square foot                                --@.000  SF      0.25         --       0.25

            Suspended Ceilings

            Remove suspended tile ceiling. (200 to 250 SF of ceiling yields one CY of debris.)
              Including suspended grid                      BL@.010   SF         --      0.33       0.33
              Including grid in salvage condition           BL@.019   SF         --      0.62       0.62

            Install suspended ceiling. Working from a ladder at heights 8' to 12' above floor level. No light fixtures
            included. Suspended from wires attached to wood joists through holes broken in drywall, plaster or
            fiberboard ceiling.
              24" x 24" ceiling grid with panels           BC@.042    SF         --      1.69       1.69
              24" x 48" ceiling grid with panels           BC@.028    SF         --      1.13       1.13
              48" x 48" ceiling grid with panels           BC@.025    SF         --      1.01       1.01
              Add for job setup, per room                  BC@.183    Ea         --      7.37       7.37

            Remove and replace 24" x 48" ceiling panels on an existing grid.
              No cutting of panels, per panel              BC@.052    Ea         --      2.09       2.09
              10% of panels cut, per panel                 BC@.059    Ea         --      2.38       2.38
              20% of panels cut, per panel                 BC@.064    Ea         --      2.58       2.58
              30% of panels cut, per panel                 BC@.070    Ea         --      2.82       2.82
              40% of panels cut, per panel                 BC@.076    Ea         --      3.06       3.06
              50% of panels cut, per panel                 BC@.082    Ea         --      3.30       3.30
   308   309   310   311   312   313   314   315   316   317   318