Page 659 - 2018 National Home Improvement
P. 659

2018 National Home Improvement Estimator, All Rights Reserved                                   Page 530



            Pressure wash building interior. Add the cost of equipment rental.
              Floors and walls, per SF washed               B8@.002   SF         --      0.08       0.08
              HVAC vent or register                         B8@.033   Ea         --      1.30       1.30
            Deploy and remove a 6" high re-usable plastic berm at the building
              perimeter                                     B8@.010   LF      1.12       0.39       1.51
            Ultrasonic cleaning of building contents, dishes, jewelry, art objects, etc. Using a 10 gallon countertop
            ultrasonic cleaner. 1.3 CF basket. Add the cost of equipment rental.
              Per load, 5 minute cleaning cycle             B8@.167   Ea         --      6.56       6.56
              Cleaning solution, per diluted gallon          --@.000 Gal      4.63         --       4.63

            Remove appliances. Disconnect, wrap unit in a pad, mount on a hand dolly and move to a new
            location on the same site for cleaning or disposal. Removal of gas and oil appliances includes closing
            and locking the gas or oil line. Per appliance.
              Most electric appliances                      B8@.485   Ea         --    19.05      19.05
              Most gas and oil appliances                   B8@.667   Ea         --    26.19      26.19
              Water heater, drain and remove                B8@.667   Ea         --    26.19      26.19
              Undercounter dishwasher                       B8@.900   Ea         --    35.34      35.34
              Undercounter trash compactor                  B8@.250   Ea         --      9.82       9.82
              Undercounter refrigerator                     B8@.250   Ea         --      9.82       9.82
              Wall oven or microwave                        B8@.450   Ea         --    17.67      17.67
              Range hood                                    B8@.500   Ea         --    19.64      19.64
              Garbage disposer                              B8@.600   Ea         --    23.56      23.56
              Add for re-installing appliances                     --  %        --       90.0         --

            Remove fixtures. Includes turning off the water, disconnecting the drain, capping supply and waste
            lines, disconnecting faucets and fittings and stack on site.
            Self-rimming sink                               B8@1.00   Ea         --    39.27      39.27
            Ledge-type or hudee ring sink                   B8@1.65   Ea         --    64.80      64.80
            Self-rimming sink with disposer                 B8@1.50   Ea         --    58.91      58.91
            Ledge-type or hudee ring sink with disposer     B8@2.00   Ea         --    78.54      78.54
            Bathtub                                         B8@2.00   Ea         --    78.54      78.54
            Toilet or bidet                                 B8@.550   Ea         --    21.60      21.60
            Vanity cabinet with sink                        B8@1.25   Ea         --    49.09      49.09
            Electric switch or receptacle and plate         B8@.110   Ea         --      4.32       4.32
            Pendent, wall or recessed light fixture         B8@.295   Ea         --    11.58      11.58
            Add for re-installing fixtures                         --  %        --       90.0         --

            HVAC system cleaning.
              Heat pump, disconnect, unbolt, remove         B8@2.33   Ea         --    91.50      91.50
              Air handler, clean and dry out interior, replace filters
               lubricate fan bearing, perform test          B8@.450   Ea      6.95     17.67      24.62
              Air handler, disconnect, unbolt, remove       B8@.750   Ea         --    29.45      29.45
              Register or drop, clean                       B8@.240   Ea         --      9.43       9.43
              HVAC duct, clean per NADCA standards. Per LF of duct.
               Typical home has 150 LF of duct.             B8@.050   LF         --      1.96       1.96
              Environmental control, remove, dry, clean, inspect,
               replace and test                             B8@.500   Ea         --    19.64      19.64