Pressure wash building interior. Add the cost of equipment rental.
Floors and walls, per SF washed B8@.002 SF -- 0.08 0.08
HVAC vent or register B8@.033 Ea -- 1.30 1.30
Deploy and remove a 6" high re-usable plastic berm at the building
perimeter B8@.010 LF 1.12 0.39 1.51
Ultrasonic cleaning of building contents, dishes, jewelry, art objects, etc. Using a 10 gallon countertop
ultrasonic cleaner. 1.3 CF basket. Add the cost of equipment rental.
Per load, 5 minute cleaning cycle B8@.167 Ea -- 6.56 6.56
Cleaning solution, per diluted gallon --@.000 Gal 4.63 -- 4.63
Remove appliances. Disconnect, wrap unit in a pad, mount on a hand dolly and move to a new
location on the same site for cleaning or disposal. Removal of gas and oil appliances includes closing
and locking the gas or oil line. Per appliance.
Most electric appliances B8@.485 Ea -- 19.05 19.05
Most gas and oil appliances B8@.667 Ea -- 26.19 26.19
Water heater, drain and remove B8@.667 Ea -- 26.19 26.19
Undercounter dishwasher B8@.900 Ea -- 35.34 35.34
Undercounter trash compactor B8@.250 Ea -- 9.82 9.82
Undercounter refrigerator B8@.250 Ea -- 9.82 9.82
Wall oven or microwave B8@.450 Ea -- 17.67 17.67
Range hood B8@.500 Ea -- 19.64 19.64
Garbage disposer B8@.600 Ea -- 23.56 23.56
Add for re-installing appliances -- % -- 90.0 --
Remove fixtures. Includes turning off the water, disconnecting the drain, capping supply and waste
lines, disconnecting faucets and fittings and stack on site.
Self-rimming sink B8@1.00 Ea -- 39.27 39.27
Ledge-type or hudee ring sink B8@1.65 Ea -- 64.80 64.80
Self-rimming sink with disposer B8@1.50 Ea -- 58.91 58.91
Ledge-type or hudee ring sink with disposer B8@2.00 Ea -- 78.54 78.54
Bathtub B8@2.00 Ea -- 78.54 78.54
Toilet or bidet B8@.550 Ea -- 21.60 21.60
Vanity cabinet with sink B8@1.25 Ea -- 49.09 49.09
Electric switch or receptacle and plate B8@.110 Ea -- 4.32 4.32
Pendent, wall or recessed light fixture B8@.295 Ea -- 11.58 11.58
Add for re-installing fixtures -- % -- 90.0 --
HVAC system cleaning.
Heat pump, disconnect, unbolt, remove B8@2.33 Ea -- 91.50 91.50
Air handler, clean and dry out interior, replace filters
lubricate fan bearing, perform test B8@.450 Ea 6.95 17.67 24.62
Air handler, disconnect, unbolt, remove B8@.750 Ea -- 29.45 29.45
Register or drop, clean B8@.240 Ea -- 9.43 9.43
HVAC duct, clean per NADCA standards. Per LF of duct.
Typical home has 150 LF of duct. B8@.050 LF -- 1.96 1.96
Environmental control, remove, dry, clean, inspect,
replace and test B8@.500 Ea -- 19.64 19.64