Page 59 - MetroSelect Single-Line Configuration Guide
P. 59

10


              RS232



                               *  Enable RS232 Mode – The scanner will work
            ³  4  1  5  5  5  4    with RS232 +/-12V serial output.

          Parity Features

          A parity bit is an extra data bit used to help catch data transmission errors.
          The scanner’s parity must match the host’s parity.
                                No Parity
            ³  3  1  6  0  4  5
                                Odd Parity – Select to set the parity bit to either a

            ³  3  1  6  0  0  5    1 or a 0 to ensure an odd number of bits are 1s.
                               *  Space Parity – Select to set the parity bit

            ³  3  1  6  0  1  5    always to 0.
                                  Even Parity – Select to set the parity bit to either
            ³  3  1  6  0  2  5    a 1 or 0 to ensure an even number of bits are 1s.

                                Mark Parity – Select Mark Parity to set the parity
            ³  3  1  6  0  3  5    bit always to 1.

          Baud Rate


                                115200 BAUD Rate
            ³  4  1  5  8  1  0  0    (Not available with Voyager)

                                57600 BAUD Rate
            ³  4  1  5  8  9  0    (Not available with Voyager)

                                38400 BAUD Rate
            ³  4  1  5  8  8  0

                                19200 BAUD Rate
            ³  4  1  5  8  7  0

                                14400 BAUD Rate
            ³  4  1  5  8  6  0



                                                                     10–1