Page 61 - MetroSelect Single-Line Configuration Guide
P. 61
* Character RTS/CTS – Activates/Deactivates
³ 1 1 5 8 1 5 RTS signal for each character.
Message RTS/CTS – Activates RTS before
³ 1 1 5 8 0 5 sending the first character and leaves it active
until after the last character has been
transmitted.
Invert RTS Polarity (RSV1)
³ 1 2 4 5 1 0 -12V = Active +12V = Inactive
* Standard RTS Polarity – Use standard RTS
³ 1 2 4 5 0 0 polarity
-12V = Inactive +12V = Active
Invert CTS Polarity (RSV2)
³ 1 2 4 5 1 1 -12V = Active, +12V = Inactive,
OK to send Do not send
* Standard CTS Polarity
³ 1 2 4 5 0 1 -12V = Inactive, +12V = Active,
Do not send OK to send
Activate RTS, Do Not Wait for CTS (RSV3) –
³ 1 2 4 5 1 2 Activate RTS for transmission but do not wait for
CTS to send.
* Activate RTS, Wait for CTS – Wait for CTS after
³ 1 2 4 5 0 2 activating RTS.
Test CTS Not Present Before RTS (RSV4) – Do
³ 1 2 4 5 1 3 not activate RTS if CTS is already present.
* Do Not Test for CTS Present Before RTS
³ 1 2 4 5 0 3
Enable DTR Support – The scanner will stop
³ 1 1 5 8 1 7 scanning when the Data Terminal Ready (DTR)
signal goes inactive.
* Disable DTR Support
³ 1 1 5 8 0 7
10–3