Page 144 - Chem Service 2016 Catalogue
P. 144
METHOD 508 - CHLORINATED PESTICIDES AND PCBs
Method 508 is applicable to the determination of chlorinated pesticides in ground water and finished drinking water by gas chromatography
with an electron capture detector.
Method 508.1 is applicable for the determination of twenty-nine chlorinated pesticides, three herbicides and four organohalides in drinking
water, ground water, and drinking water in any treatment stage using liquid-solid extraction and electron capture gas chromatography. EPA 500
Method 508A is applicable for screening of Polychlorinated Biphenyls by gas chromatography and may be used for screening finished drinking
water, raw source water, or drinking water in any treatment stage for polychlorinated biphenyls (PCBs).
ORGANOCHLORINE PESTICIDES MIXTURE #1
EPA METHOD 508, 508.1, 525.2, 608, 617, 625, 8080A/8081, 8250A/8270B, CLP
Aldrin (TM) b-Endosulfan BHC (alpha isomer) BHC (beta isomer)
BHC (delta isomer) cis-Chlordane 4,4’-DDD 4,4’-DDE
4,4’-DDT Dieldrin a-Endosulfan Endosulfan sulfate
Endrin Endrin aldehyde Endrin ketone Heptachlor
Heptachlor epoxide (Isomer B) Lindane (BHC gamma isomer) Methoxychlor trans-Chlordane
1000ug/mL in tert-Butyl methyl ehter (20 components)
M-OCP5081T4-1ML 1mL Ampule
ORGANOCHLORINE PESTICIDES MIXTURE #2 ORGANOCHLORINE PESTICIDES MIXTURE #3
EPA METHOD 508/508.1, 525.2 EPA METHOD 508.1
Chlorobenzilate Chloroneb Alachlor Atrazine
Chlorothalonil Chlorthal-dimethyl Bladex Hexachlorocyclopentadiene
Etridiazole Hexachlorobenzene Metolachlor Metribuzin
Permethrin Propachlor Simazine
Trifluralin
500 ug/ml in Ethyl acetate (7 components)
1000ug/mL in tert-Butyl methyl ether (9 components) M-OCP5083H3-1ML 1mL Ampule
M-OCP5082T4-1ML 1mL Ampule
ORGANOCHLORINE PESTICIDES MIXTURES
EPA METHOD 508/508.1, 608, 617, 625, 8080A/8081, 8250A/8270B, CLP
Aldrin (TM) b-Endosulfan BHC (alpha isomer) BHC (beta isomer)
BHC (delta isomer) 4,4’-DDD 4,4’-DDE 4,4’-DDT
Dieldrin a-Endosulfan Endosulfan sulfate Endrin
Endrin aldehyde Heptachlor Heptachlor epoxide (Isomer B)
Lindane (BHC gamma isomer) Methoxychlor
100 ug/ml in Toluene:Hexane (50:50) (17 components)
M-OCP8080AC1-1ML 1mL Ampule
100 ug/ml in Toluene:Hexane (50:50), less Methoxychlor (16 components)
M-PPO8AC1-1ML 1mL Ampule
2000 ug/ml in Toluene:Hexane (50:50), less Methoxychlor (16 components)
M-PPHC5AC5-1ML 1mL Ampule
LABORATORY PERFORMANCE CHECK DEGRADATION CALIBRATION MIXTURE
MIXTURE EPA METHOD 508/508.1, 525.2, 608, 617, 625,
EPA METHOD 508/508.1 1618, 1656, 8080A/8081, 8250A/8270B, CLP
40ug/mL BHC (delta isomer) 200ug/mL 4,4’-DDT
50ug/mL Chlorothalonil 100ug/mL Endrin
2ug/mL Chlorpyrifos
50ug/mL Chlorthal-dimethyl Varied concenration in tert-Butylmethyl ether (2 components)
M-DC508T99-1ML 1mL Ampule
Varied concenration in tert-Butylmethyl ether (4 components)
M-LPC508T99-1ML 1mL Ampule DEGRADATION PRODUCTS MIXTURE
EPA METHOD 508/508.1, 525.2, 608, 617, 625,
1618, 1656, 8080A/8081, 8250A/8270B, CLP
200ug/mL 4,4’-DDD
200ug/mL 4,4’-DDE
100ug/mL Endrin aldehyde
100ug/mL Endrin ketone
Varied concenration in tert-Butylmethyl ether (4 components)
M-DP5081T99-1ML 1mL Ampule
143