Page 355 - Wurth Total Catalogue
P. 355

techniglue ca ®



                                                                                 Techniglue CA is a solvent free, epoxy
                                                                                 resin, specially formulated to harden
                                                                                 at room temperature and produce
                                                                                 high-strength, waterproof bonds. The
                                                                                 thixotropic nature of the adhesive
                                                                                 provides good gap filling and hold-up
                                                                                 on vertical surfaces.

                                                                                 It is suitable for bonding structural
                                                                                 elements fabricated from wood,
                                                                                 concrete, fibreglass, stone and marble,
                                                                                 pottery, metal (ferrous and non-ferrous)
                                                                                 and some plastics.

                                                                                 Description    Art. No.   Pack Qty.
                                                                                 1.5kg kit      0893 481   1

                                                                                 Description    Art. No.   Pack Qty.
                                                                                 Cartridge 450ml  0893 483  1
                                                                                 Cartridge gun  0891 893 48 1


                                                                                 Safety:
                                                                                 Techniglue CA has a moderate sensitising
                                                                                 potential, and should be kept out of the eyes and
                                                                                 off the skin.

                                                                                 •  Use only with good ventilation and adequate
       Application:                                                                PPE equipment – impervious gloves and safety
       The surfaces to be bonded must be dry and free from any contaminants such as oil or dust.   glasses.
       Fibreglass, timber, painted or metal surfaces should be thoroughly sanded in order to provide a good
       key with the adhesive. Concrete surfaces should be wire brushed to remove laitance*.  Storage:
       Apply sufficient mixed epoxy to one or both of the surfaces to assure intimate contact between bonding   Techniglue CA will keep for 2 years if kept in the
       surfaces. Excessive clamping pressures should be avoided. Components need only be held firmly to   original containers at room temperature (15°C
       avoid movement during the curing process.                                 to 32°C) and out of direct sunlight. Containers
                                                                                 and cartridges should be firmly sealed after use to
       Mixing Ratio:                                                             prevent moisture absorption.
       1 x part hardener to 2 x parts resin by volume. Take care to assure that the two components are tho-
       roughly mixed to a uniform colour prior to applying.
                                                                                 Coverage:
                                                                                 Depending on porosity and surface roughness,
       An easy way to mix the bulk tin version of this product is to dispense 3 x equal portions – 2 x of resin   one litre of mixed Techniglue CA will cover appro-
       and 1 x of hardener. This way you can judge more easily that the mixing ration has been achieved.   ximately 3m².
       (This is not necessary, of course, with the cartridge version of the product as it mixes correctly out of the
       cartridge as you apply it.)
                                                                                 Clean Up:
                                                                                 Uncured Techniglue CA resin and hardener can
                                                                                 be cleaned up with warm water.
       * Laitance is the weak, milky or powdery layer of cement dust, lime and sand fines that may appear on
       the surface of concrete. These fines rise to the surface of concrete that was over-watered, or allowed to
       dry prematurely in the absence of curing membranes or other good curing practices. It may also form as
       a consequence of over-trowelling.

     AUS. pub. 01/14 ©





                                                         05 4371