Page 999 - Wurth Total Catalogue
P. 999

VDE COMBINATION PLIERS




                                                                                 Standard: DIN ISO 5746, IEC 900, EN 60900.
                                                                                 Handle: Zebra Insulated, 2-Components, hand
                                                                                 slip protection.
                                                                                 Cutting edge: For hard and soft wire, long cutting
                                                                                 edges, inductively hardened.
                                                                                 Joint: Lap.
                                                                                 Head: Chrome-plated.
                                                                                 Torch hole: Gripping of round  materials.

                                                                                 •   Routine check test in a water bath with test
                                                                                   voltage 10 kV.
        L       L        Diameter  Diameter  Diameter      Art. No.      Pack    •   For work under voltages up to 1,000 volts
        in mm   in inches  in mm  in mm   in mm   in mm2                 Qty       (AC), up to 1,500 volts (DC).
        170     6 1/4    3.1     2.0      10      16       0714 01 574   1       •   denti cation marking with the year of
        180     7        3.4     2.2      12      16       0714 01 575             manufacture.
        200     8        3.8     2.5      13      16       0714 01 576









          VDE SIDE CUTTING PLIERS



                                                                                 Standard: DIN ISO 5749, IEC 900, EN 60900.
                                                                                 Handle: Zebra Insulated, 2-Components,
                                                                                 hand slip protection.
                                                                                 Cutting edge: For hard and soft wire, inductively
                                                                                 hardened precision cutting edges.
                                                                                 Joint: Lap.
                                                                                 Head: Chrome-plated.

                                                                                 •   Routine check test in a water bath with test
                                                                                   voltage 10 kV.
                                                                                 •   For work under voltages up to 1,000 volts
                                                                                   (AC), up to 1,500 volts (DC).
                                                                                 •   denti cation marking with the year of
                                                                                   manufacture.
        L       L           Diameter  Diameter  Diameter  Art. No.   Pack Qty.
        in mm   in inches   in mm   in mm    in mm
        160     6 1/4       4.0     2.8      2.0     0714 01 572     1








                                                                                            Soft Wire

                                                                                            Medium-hard Wire
      AUS. pub. 04/15 ©                                                                     Hard Wire


                                                                                            Cu + Al Cables

                                                         12 2081
   994   995   996   997   998   999   1000   1001   1002   1003   1004