Page 2289 - Foton Workshop Manual - Aumark (BJ1099)
P. 2289

DIAGNOSIS-HEATER & AIR CONDITIONING                          62-237

                                                            (d).   Measure the resistance according to values
                                                                   in the table below.
                                                                        Standard resistance: (check whether there
                                                                   is an open circuit)

                                                                     Connect the pin by      Standard value         62
                                                                         multimeter

                                                                       C42(B4)-C52(1)
                                                                       C42(A8)-C52(2)

                                                                       C42(A4)-C52(3)              < 2Ω

                                                                       C42(A12)-C52(5)

                                                                       C42(B12)-C52(6)
                 Is the result normal?
                 Yes>To step 3.
                 No >Repair or replace the harness.


                 3.     Check temperature regulation servo motor


                 (a).   Ignition switch:"LOCK".
                 (b).   Disconnect temperature regulation servo motor connector C52.


                                                            (c).   Check the function of temperature
                                                                   regulation servo motor C52.
                    OFF
                                                    C52                              Connect the  Specified
                                                                      Conditions
                                                                                           pins         value
                                         6  5  3  2  1
                                                                                       Battery (+)-5
                                                                    Apply the battery                 Temperature
                                                                     voltage between                  regulation

                                                 fuwx62 656           the No. 5 and     Battery(-)-6  servo motor
                                                                        No. 6 pin
                                                                                                       run
                 Is the result normal?
                 Yes >Replace the A/C control.
                 No >Replace temperature  regulation servo motor, validate again whether this fault exists