Page 2292 - Foton Workshop Manual - Aumark (BJ1099)
P. 2292

62-240                      DIAGNOSIS-HEATER & AIR CONDITIONING


                                                      (d).    Measure the resistance according to values
                                                              in the table below.
                                                              Standard resistance: (check whether there
                                                              is an open circuit)


                                                               Connect the pin by       Standard value
                                                                   multimeter
                                                                  C42(B4)-C38(1)

                                                                  C42(A7)-C38(2)
                                                                                             < 2Ω
                                                                  C42(A4)-C38(3)

                                                                 C42(A11)-C38(5)
                                                                 C42(B11)-C38(6)


           Is the result normal?
           Yes>To step 3.
           No >Repair or replace the harness.


           3.     Check cycle  servo motor


           (a).   Ignition switch:"LOCK".
           (b).   Disconnect cycle servo motor connector C38.


                                                      (c).    Check the function of cycle servo motor
                                                              C38.
              OFF
                                              C38                               Connect the  Specified
                                                                 Conditions
                                   6  5  3  2  1                                     pins          value
                                                                  Apply the       Battery (+)-5
                                                                battery voltage                  Cycle servo
                                                                 between the
                                           fuwx62  657                            Battery(-)-6   motor run
                                                                No.5 and No.6
                                                                     pin
           Is the result normal?
           Yes>Replace the A/C control.
           No >Replace cycle  servo motor, validate again whether this fault exists or not.