DIAGNOSIS-HEATER & AIR CONDITIONING 62-209
(c). Measure the resistance according to values
in the table below.
Standard resistance: (check whether there
is an open circuit)
Connect the pin by Standard value 62
multimeter
F17(5A)—C42(A3) < 2 Ω
Is the result normal?
Yes>To step 3.
No >Repair or replace the harness.
3. Check the wiring harness and connectors (interior fuse F33 - air conditioning
controller)
(a). Disconnect the battery negative cable.
(b). Disconnect air conditioning controller connector C42.
(c). Measure the resistance according to values
in the table below.
Standard resistance: (check whether there
is an open circuit)
Connect the pin by Standard value
multimeter
F33(5A)—C42(A1) < 2 Ω
Is the inspection result normal?
Yes>To step4.
No >Repair or replace the harness.