62-214                      DIAGNOSIS-HEATER & AIR CONDITIONING


           Is the result normal?
           Yes>To step5.
           No >Repair or replace the harness.


           5.     Check front blower motor


           (a).   Ignition switch:"LOCK".



                                                      (b).    Disconnected front blower connector C40.





















                                           fuwx62  613

                                                      (c).    Check the function of front blower motor.


                                                                                Connect the  Specified
                                                                Conditions
                                                                                     pins          value
                                                                  Apply the       Battery (+)-1
                                                                battery voltage                    Front
                                                                 between the                       blower
                                                               No. 1 and No. 2    Battery(-)-2   motor run
                                                                     pin
           Is the result normal?
           Yes>To step 7.
           No >Replace the front blower motor.


           6.     Check the wiring harness and connectors (front blower motor - front blower speed
                  regulation resistance)


           (a).   Disconnect the battery negative cable.














                                                                                                     Page 2266