Page 2379 - Foton Workshop Manual - Sauvana
P. 2379

DIAGNOSIS-LIGHTING SYSTEM                               62-327

                                                            (b).   Measure the resistance between both the

                   OFF           T.S           Ω                   terminal of the connector C57 on the
                                                                   body controller and the grounding with
                                                                   a multimeter. D14 between terminal and
                                       C57
                                                                   earthing resistance.
                          16 15  14  13 12  11 10 9  8  7  6  5  4  3  2  1                                         62
                          32 31  30 29  28  27 26  25  24 23 22  21  20 19 18 17     Standard resistance: (check whether there
                                                                   is a short circuit)

                                                 fuwx62 891
                                                                     Connect the pin by      Standard value
                                                                         multimeter
                                                                     C57 (D14) - Grounding       > 1 MΩ

                 Is the inspection result normal?
                 Yes>To step 3.
                 No >Repair or replace the harness of the short circuit to ground between C57 and the high
                        beam relay R6.


                 3.     Check the combination switch


                 (a).   Ignition switch:"LOCK".
                 (b).   Disconnect the combination switch connector C16.
                 (c).    Turn the combination switch to the "high beam lamp" gear.


                                                             (d).   Measure the combination switch connector
                                                                   C16 with a multimeter.


                                                                     Connect the pin by      Specified value
                                                                         multimeter

                                                                            20 - 19              not existed





                 Is the inspection result normal?
                 Yes>To step 4.
                 No >Replace the combination switch.


                 4.     Detect the short circuit to ground of the combination switch


                 (a).   Ignition switch:"OFF".
                 (b).   Disconnect the combination switch connector C16.
                 (c).    Turn the combination switch to the "high beam lamp" gear.











                                                                                                     Page 2379