Page 2379 - Foton Workshop Manual - Sauvana
P. 2379
DIAGNOSIS-LIGHTING SYSTEM 62-327
(b). Measure the resistance between both the
OFF T.S Ω terminal of the connector C57 on the
body controller and the grounding with
a multimeter. D14 between terminal and
C57
earthing resistance.
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 62
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 Standard resistance: (check whether there
is a short circuit)
fuwx62 891
Connect the pin by Standard value
multimeter
C57 (D14) - Grounding > 1 MΩ
Is the inspection result normal?
Yes>To step 3.
No >Repair or replace the harness of the short circuit to ground between C57 and the high
beam relay R6.
3. Check the combination switch
(a). Ignition switch:"LOCK".
(b). Disconnect the combination switch connector C16.
(c). Turn the combination switch to the "high beam lamp" gear.
(d). Measure the combination switch connector
C16 with a multimeter.
Connect the pin by Specified value
multimeter
20 - 19 not existed
Is the inspection result normal?
Yes>To step 4.
No >Replace the combination switch.
4. Detect the short circuit to ground of the combination switch
(a). Ignition switch:"OFF".
(b). Disconnect the combination switch connector C16.
(c). Turn the combination switch to the "high beam lamp" gear.
Page 2379