Page 2439 - Foton Workshop Manual - Sauvana
P. 2439

DIAGNOSIS-LIGHTING SYSTEM                               62-387

                 3.     Check harness disconnection (Body controller - Left daytime running light)


                 (a).   Disconnect left daytime running light connector A44, body controller C56.


                                                            (b).   Use a multimeter to measure the resistance
                                                                   between No. 1 terminal of connector A44          62
                                                                   and No. 11 terminal of connector C56.
                                                                   Standard resistance: (check whether there
                                                                   is an open circuit)

                                                                     Connect the pin by      Standard value
                                                                         multimeter
                                                                       A44(1) - C56(11)            ≤ 2 Ω



                                                            (c).   Use a multimeter to measure the resistance
                                                                   between No. 2 terminal of the left daytime
                   OFF           T.S
                                            Ω                      running light connector A44 and the
                                                                   ground.
                                                                   Standard resistance: (check whether there
                   A 44
                                                                   is an open circuit)
                       1    2
                                                                     Connect the pin by
                                                 fuwx62 948                                  Standard value
                                                                         multimeter
                                                                      A44(2) - Grounding           ≤ 2 Ω

                 Is the inspection result normal?
                 Yes>Find the causes from other symptoms.
                 No >Repair the harness disconnection between connector A44 and C56, A44 and the
                         ground.


































                                                                                                     Page 2439
   2434   2435   2436   2437   2438   2439   2440   2441   2442   2443   2444