Page 1000 - Foton Workshop Manual - Tunland (AT)
P. 1000
04-854 DIAGNOSTICS - LIGHTING SYSTEM
(e) Measure the electrical resistance based on
the value in the following form.
Standard electrical resistance (check
A011
whether there existent an open circuit)
1 2 3 Multimeter connection Standard value
4 5 6
04
A011 (5) - ground
< 2 Ω
A003 A003 (5) - ground
1 2 3
4 5 6
ftwxd041001
Check whether the result is normal?
Yes> go to step 7
No > Maintenance or replace harness.
7 . Check the harness and connectors (passing lamp relay - BCM control unit)
(a) Ignition Switch: OFF.
(b) Unplug the fog lamp relay R2.
(c) Disconnect connector C035, BCM control unit.
ftwxd041025
(d) Measure the electrical resistance based on
the value in the following form.
Standard electrical resistance (check
whether there existent an open circuit)
C035
Multimeter connection Standard value
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17
R2(2)-C035(D6) < 2 Ω
2
4 5 3 R2
1
ftwxd041002
Page 1000