Page 137 - Foton Workshop Manual - Tunland (AT)
P. 137

CIRCUIT - VOLTAGE IS BELOW                       P3361-INTAKE MANIFOLD 1 PRESSURE
                    NORMAL OR SHORTED TO LOW                         - ABNORMAL UPDATE RATE .....04-252
                    VOLTAGE POWER SUPPLY. ........04-233             P691,P692-TURBOCHARGER 1
                    P1242,P2185,P2186-ACCELERATOR                    COMPRESSOR INLET TEMPERATURE
                    PEDAL OR LEVER POSITION SENSOR                   CIRCUIT P691-TURBOCHARGER 1
                    1 AND 2 - THE DATA IS UNSTABLE,                  COMPRESSOR INLET TEMPERATURE
                                                                                                                     04
                    INTERMITTENT OR INCORRECT                        CIRCUIT -VOLTAGE IS ABOVE NORMAL
                    P1242-ACCELERATOR PEDAL OR                       OR SHORTED TO HIGH VOLTAGE
                    LEVER POSITION SENSOR 1 AND 2 -                  POWER SUPPLY
                    THE DATA IS UNSTABLE,                            P692-TURBOCHARGER 1
                    INTERMITTENT OR INCORRECT                        COMPRESSOR INLET TEMPERATURE
                    P2185-SENSOR POWER 4 CIRCUIT -                   CIRCUIT -VOLTAGE IS BELOW NORMAL
                    VOLTAGE IS ABOVE NORMAL OR                       OR SHORTED TO HIGH VOLTAGE
                    SHORTED TO HIGH VOLTAGE POWER                    POWER SUPPLY .........................04-256
                    SUPPLY P2186-SENSOR POWER 4                      P1228,P2271,P2272-EXHAUST GAS
                    CIRCUIT - VOLTAGE IS BELOW                       RECIRCULATION (EGR) VALVE
                    NORMAL OR SHORTED TO LOW                         POSITION P1228-EXHAUST GAS
                    VOLTAGE POWER SUPPLY ........04-237              RECIRCULATION (EGR) VALVE
                    P1695,P1696-SENSOR POWER 5                       POSITION - DATA IS UNSTABLE,
                    FAULT P1695-SENSOR POWER 5                       INTERMITTENT OR INCORRECT
                    CIRCUIT - VOLTAGE IS ABOVE                       P2271-EGREGR VALVE POSITION
                    NORMAL OR SHORTED TO HIGH                        CIRCUIT - VOLTAGE IS ABOVE
                    VOLTAGE POWER SUPPLY                             NORMAL OR SHORTED TO HIGH
                    P1696-SENSOR POWER 5 CIRCUIT -                   VOLTAGE POWER SUPPLY P2272-EGR
                    VOLTAGE IS BELOW NORMAL OR                       VALVE POSITION CIRCUIT - VOLTAGE
                    SHORTED TO LOW VOLTAGE POWER                     IS BELOW NORMAL OR SHORTED TO
                    SUPPLY .......................................04-241  LOW VOLTAGE POWER SUPPLY
                    P1938,P1938,P1941,P2198-ECU                      ......................................................04-260
                    POWER OUTPUT VOLTAGE FAULT                       P1664,P3158-POSTPROCESSING
                    P1938-ECU POWER OUTPUT VOLTAGE                   DIESEL OXIDATION CONVERTER
                    1 - DATA IS VALID BUT BELOW                      MISSING FAULT
                    NORMAL OPERATING RANGE -                         P1664-POSTPROCESSING DIESEL
                    MEDIUM SEVERITY LEVEL P1939-ECU                  OXIDATION CONVERTER MISSING -
                    POWER OUTPUT VOLTAGE 1 -                         THE CONDITION EXISTS
                    VOLTAGE IS ABOVE NORMAL OR                       P3158-POSTPROCESSING PREHEAT
                    SHORTED TO HIGH VOLTAGE POWER                    DIESEL OXIDATION CONVERTER
                    SUPPLY P1941-ECUECU POWER                        MISSING - THE CONDITION EXISTS
                    OUTPUT VOLTAGE 1 - VOLTAGE IS                    ......................................................04-265
                    BELOW NORMAL OR SHORTED TO                       P1691-POSTPROCESSING DIESEL
                    LOW VOLTAGE POWER SUPPLY                         OXIDATION CONVERTER SYSTEM
                    P2198-VARIABLE GEOMETRY                          EFFICIENCY - DATA IS VALID BUT
                    TURBOCHARGER ACTUATOR DRIVE                      BELOW NORMAL OPERATING RANGE
                    CIRCUIT - ROOT CAUSE UNKNOWN                     - MEDIUM SEVERITY LEVEL .....04-270
                    ......................................................04-242  P1879,P1881,P1921,P1922,
                    P3243-ENGINE COOLING SYSTEM                      P1993,P2639,
                    MONITOR - DATA VALID BUT BELOW                   P3168-POSTPROCESSING DIESEL
                    NORMAL OPERATING RANGE -                         PARTICULATE FILTER DIFFERENTIAL
                    MEDIUM SEVERITY LEVEL .......04-248              PRESSURE FAULT
                                                                     P1879-POSTPRECESSING DIESEL




                                                                                                         Page 137
   132   133   134   135   136   137   138   139   140   141   142