Page 137 - Foton Workshop Manual - Tunland (AT)
P. 137
CIRCUIT - VOLTAGE IS BELOW P3361-INTAKE MANIFOLD 1 PRESSURE
NORMAL OR SHORTED TO LOW - ABNORMAL UPDATE RATE .....04-252
VOLTAGE POWER SUPPLY. ........04-233 P691,P692-TURBOCHARGER 1
P1242,P2185,P2186-ACCELERATOR COMPRESSOR INLET TEMPERATURE
PEDAL OR LEVER POSITION SENSOR CIRCUIT P691-TURBOCHARGER 1
1 AND 2 - THE DATA IS UNSTABLE, COMPRESSOR INLET TEMPERATURE
04
INTERMITTENT OR INCORRECT CIRCUIT -VOLTAGE IS ABOVE NORMAL
P1242-ACCELERATOR PEDAL OR OR SHORTED TO HIGH VOLTAGE
LEVER POSITION SENSOR 1 AND 2 - POWER SUPPLY
THE DATA IS UNSTABLE, P692-TURBOCHARGER 1
INTERMITTENT OR INCORRECT COMPRESSOR INLET TEMPERATURE
P2185-SENSOR POWER 4 CIRCUIT - CIRCUIT -VOLTAGE IS BELOW NORMAL
VOLTAGE IS ABOVE NORMAL OR OR SHORTED TO HIGH VOLTAGE
SHORTED TO HIGH VOLTAGE POWER POWER SUPPLY .........................04-256
SUPPLY P2186-SENSOR POWER 4 P1228,P2271,P2272-EXHAUST GAS
CIRCUIT - VOLTAGE IS BELOW RECIRCULATION (EGR) VALVE
NORMAL OR SHORTED TO LOW POSITION P1228-EXHAUST GAS
VOLTAGE POWER SUPPLY ........04-237 RECIRCULATION (EGR) VALVE
P1695,P1696-SENSOR POWER 5 POSITION - DATA IS UNSTABLE,
FAULT P1695-SENSOR POWER 5 INTERMITTENT OR INCORRECT
CIRCUIT - VOLTAGE IS ABOVE P2271-EGREGR VALVE POSITION
NORMAL OR SHORTED TO HIGH CIRCUIT - VOLTAGE IS ABOVE
VOLTAGE POWER SUPPLY NORMAL OR SHORTED TO HIGH
P1696-SENSOR POWER 5 CIRCUIT - VOLTAGE POWER SUPPLY P2272-EGR
VOLTAGE IS BELOW NORMAL OR VALVE POSITION CIRCUIT - VOLTAGE
SHORTED TO LOW VOLTAGE POWER IS BELOW NORMAL OR SHORTED TO
SUPPLY .......................................04-241 LOW VOLTAGE POWER SUPPLY
P1938,P1938,P1941,P2198-ECU ......................................................04-260
POWER OUTPUT VOLTAGE FAULT P1664,P3158-POSTPROCESSING
P1938-ECU POWER OUTPUT VOLTAGE DIESEL OXIDATION CONVERTER
1 - DATA IS VALID BUT BELOW MISSING FAULT
NORMAL OPERATING RANGE - P1664-POSTPROCESSING DIESEL
MEDIUM SEVERITY LEVEL P1939-ECU OXIDATION CONVERTER MISSING -
POWER OUTPUT VOLTAGE 1 - THE CONDITION EXISTS
VOLTAGE IS ABOVE NORMAL OR P3158-POSTPROCESSING PREHEAT
SHORTED TO HIGH VOLTAGE POWER DIESEL OXIDATION CONVERTER
SUPPLY P1941-ECUECU POWER MISSING - THE CONDITION EXISTS
OUTPUT VOLTAGE 1 - VOLTAGE IS ......................................................04-265
BELOW NORMAL OR SHORTED TO P1691-POSTPROCESSING DIESEL
LOW VOLTAGE POWER SUPPLY OXIDATION CONVERTER SYSTEM
P2198-VARIABLE GEOMETRY EFFICIENCY - DATA IS VALID BUT
TURBOCHARGER ACTUATOR DRIVE BELOW NORMAL OPERATING RANGE
CIRCUIT - ROOT CAUSE UNKNOWN - MEDIUM SEVERITY LEVEL .....04-270
......................................................04-242 P1879,P1881,P1921,P1922,
P3243-ENGINE COOLING SYSTEM P1993,P2639,
MONITOR - DATA VALID BUT BELOW P3168-POSTPROCESSING DIESEL
NORMAL OPERATING RANGE - PARTICULATE FILTER DIFFERENTIAL
MEDIUM SEVERITY LEVEL .......04-248 PRESSURE FAULT
P1879-POSTPRECESSING DIESEL
Page 137