61-8        HEATER AND AIR CONDITIONING - HEATING & AIR-CONDITIONING SYSTEM

                  If not, replace the compressor assembly.

           2 .    Heater
                  Add some coolant into the heater and check for leakage.
      61
           3 .    A/C Pipe
                  Leakage test: Fill the pipes with dry helium, with 3.5 MPa in the high-pressure pipe
                  and 1.67 MPa in the low-pressure pipe. Immerse the pipes in water for 5 minutes and
                  check for bubbles.
           4 .    Evaporator

                  Leakage test: Inject the pressure of 1.67 MPa into the evaporator, immerse it in water
                  for 5 minutes and check bubbles.
           5 .    Condenser
                  Leakage test: Inject the pressure of 3.5 MPa into the condenser, immerse it in water
                  for 3 minutes and check bubbles.