DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-119


                  Failure code     Diagnostic items (DTC definition)                Trouble location
                                                                          • Intake heater
                                  Engine intake air heater 1 circuit -    • Intake heater is in poor contact,
                  P383            current is below normal or open cir-      and the relay and harness is open
                                  cuit                                      or shorted
                                                                          • ECM                                      04

                                  Sensor power 1 circuit - voltage is     • The harness between the engine
                  P386            above normal or shorted to low volt-      and the ECM is open or shorted
                                  age power supply                        • ECM

                                                                          • Oil pressure switch
                                  Engine oil rail pressure - data is valid • Oil pressure switch connector is
                  P415            but below normal operating range -        out of contact, the harness is open
                                  highest severity level                    or shorted
                                                                          • ECM

                                                                          • Fuel hydrous sensor
                                  Fuel water indicator - data is valid but • Fuel hydrous sensor connector is
                  P418            above normal operating range - low-       out of contact, the harness is open
                                  est severity level                        or shorted
                                                                          • ECM

                                                                          • Fuel hydrous sensor
                                                                          • Wiring harness, joint or sensor loop
                                  Fuel water indicator circuit - voltage    or signal circuit is open
                  P428            is above normal or shorted to high
                                                                          • Signal wire is shorted to sensor
                                  voltage power supply
                                                                            power or battery voltage
                                                                          • ECM

                                                                          • Fuel hydrous sensor
                                                                          • Wiring harness, joint or sensor loop
                                  Fuel hydrous indicator circuit - volt-
                                                                            or signal circuit is open
                  P429            age is below normal or shorted to low
                                                                          • Signal wire is shorted to sensor
                                  voltage power supply
                                                                            power or battery voltage
                                                                          • ECM
                                                                          • Oil pressure switch
                                                                          • Oil pressure switch connector is
                                  Engine oil rail pressure - Data is un-
                  P435                                                      out of contact, the harness is open
                                  stable, intermittent or incorrect
                                                                            or shorted
                                                                          • ECM

                                                                          • Battery harness or ECM connector
                                  Battery 1 voltage - data is valid but
                                                                            is out of contact, the harness is
                  P441            below normal operating range -
                                                                            open or shorted
                                  medium severity level
                                                                          • ECM