04-178                     DIAGNOSTICS - ENGINE CONTROL SYSTEM


                                                               DTC inspection
                     DTC               DTC definition                                 Trouble location
                                                                 conditions
                                     Fan control circuit -
                                       voltage is below     • When the key
                    P245            normal or short circuit   switch is turned on   • Fan
                                                                                    • The fan connector
      04                            to low voltage power      and the pulse-width
                                            supply            modulation device       is in poor contact,
                                                              is energized or         and the relay or
                                     Fan control circuit -                            harness is broken
                                       voltage is above       powered off, the        or shorted
                                                              diagnosis continues
                    P2377           normal or short circuit                         • ECM
                                    to low voltage power      to run.
                                            supply

           Diagnosis Procedure

                NOTICE

           •      To implement the following steps, ensure that ECM is grounded properly.
           •      Before conducting electric diagnosis, do refer to the reference circuit diagram
                  and the element information.
           •      Before conducting measurement, check the pins of connectors for rupture,
                  looseness and rust, and ensure that the pins are contacted properly.
           •      If the connection is good, check the sensor signal voltage when moving the
                  connector and harness. If a fault occurs, the voltage display on the diagnostic
                  instrument will change.



           1 .    DTC inspection
           (a)    Ignition switch: OFF.
           (b)    Connect the diagnostic apparatus.
           (c)    Use the diagnostic apparatus, read the fault code.
           (d)    Confirm whether there is fault code related to fan control circuit?
           Is the inspection result normal?
           YES>To step 2.

           NO>Intermittent trouble exists.

           2 .    Check fan control circuit fuse
           (a)    Ignition switch: OFF.
           (b)    Disconnect the battery negative cable.
           (c)    Unplug fan control circuit fuse F12, F16.
           (d)    Check whether fan control circuit fuse F12 and F16 is fusing or not.

           Is the inspection result normal?
           YES>To step 3.

           NO>Replace the fuse.

           3 .    Check main fan relay R5, R16 and auxiliary fan relay R4