Page 34 - Foton Workshop Manual - Tunland (AT)
P. 34
01-28 INTRODUCTION - HOW TO TROUBLESHOOT
01 Check the contact pressure at the pin:
• Prepare a male connector and insert it into
the female connector, to check the
connection and sliding resistance.
NOTICE
Use gold-plated male connector to check
gold-plated female connector.
(d) Service at Connector Pin
• If any dirt or oil, clean the contact point
with air gun or cloth. Don't polish with
sand paper, or it may damage the
plated layer.
• If the contact pressure is abnormal,
replace the female connector. In such
case, if the male connector is gold
plated, use a female gold-plated
connector. And if the male connector
is silver plated, use a female connector
in the same material.
(e) Service Precaution on Harness
• Before removing the harness, check
the positions of the harness and the
band, to faciliate reinstallation.
• Don't excessively twist, pull or hang the
harness.
• Keep the harness away from hot,
rotating, moving, vibrating or sharp
(such as panel edge or screw point)
parts.
• When installing the parts, don't clamp
or catch the harness.
• Don't cut or break the harness
insulation. In case of breakage, replace
the harness or wrap the broken part
with insulation tape.
Page 34