Page 381 - Foton Workshop Manual - Tunland (AT)
P. 381

DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-235

                                                           (f)    Use a multimeter to measure the voltage
                                                                  between the pin 2 of accelerator pedal or lever
                                                                  position sensor 2 connector A026 and the
                                                                  ground.

                                                                  Standard voltage

                                                            Multimeter connection                                    04
                                                                                           Standard value
                                                                       pin
                                                               A026(6)-ground                4.75~5.25 V










                 Is the inspection result normal?
                 YES>To step 3.
                 No > Maintain or replace the harness.


                 3 .    Check accelerator pedal or lever position sensor 2 harness
                 (a)    Ignition switch: OFF.
                 (b)    Disconnect the battery negative cable.
                 (c)    Disconnect the connector A026 of accelerator pedal or lever position sensor 2.
                 (d)    Disconnect connector A024 of ECM.

                                                           (e)    Use a multimeter to measure the resistance
                                                                  between the pin 4, 5 of accelerator pedal or
                                                                  lever position sensor 2 connector A026 and
                                                                  the pin 55, 43 of ECM connector A024
                                                                  respectively.
                                                                  Standard resistance

                                                            Multimeter connection
                                                                                           Standard value
                                                                       pin

                                                            A026(4)- A024(55)                   <10Ω
                                                            A026(5)- A024(43)                   <10Ω


























                                                                                                         Page 381