Page 549 - Foton Workshop Manual - Tunland (AT)
P. 549

DIAGNOSTICS - ENGINE CONTROL SYSTEM                          04-403

                 THE GENERATOR DOESN'T CHARGE OR CHARGE ENOUGH


                      Fault phenomenon                  Diagnosis logic                Possible reasons
                                                  • Engine Accessory Belt         • Engine Accessory Belt fault
                                                  • Charging system               • Charging system fault
                  The generator doesn't charge
                                                  • Generator                     • Generator fault
                  or charge enough                                                                                   04
                                                  • Battery                       • Battery fault
                                                  • ECM                           • ECM fault


                 Diagnosis Procedure

                 1 .    Check the engine data
                 (a)    Ignition switch: OFF.
                 (b)    Connect the diagnosis tool with the fault diagnosis connector (16 pins) on the lower
                        left of the dashboard.
                 (c)    Ignition switch: ON, and start the diagnostic tool.
                 (d)    Read the motor data shown on the diagnostic tool.
                 Check whether the data flow is normal or not.

                 YES>To step 2.
                 No >Maintenance related faults.


                 2 .    Check battery
                 (a)    Check whether battery status is normal.
                 (b)    Check whether the positive and negative cables of battery are installed correctly.
                 Is the inspection result normal?

                 YES>To step 3.
                 No >Maintenance related faults.


                 3 .    Check engine accessory belt and belt tensioner.
                 (a)    Check whether engine accessory belt is aging or damaged.
                 (b)    Check whether the belt tensioner can work normally.
                 Is the inspection result normal?

                 YES>To step 4.
                 No >Maintenance related faults.

                 4 .    Check generator and its harness
                 (a)    Check whether the generator can work properly.
                 (b)    Use a multimeter to measure whether the harness between the generator and the
                        battery are normal.

                 Is the inspection result normal?
                 YES>To step 5.

                 No >Maintenance related faults.






                                                                                                         Page 549
   544   545   546   547   548   549   550   551   552   553   554