Page 713 - Foton Workshop Manual - Tunland (AT)
P. 713

DIAGNOSTICS - REVERSE RADAR SYSTEM                           04-567

                 Yes> go to step 3.

                 No > Maintenance or replace harness.

                 3 .    Check harness and connector (reverse radar probe - ground)
                 (a)    Ignition Switch: OFF.
                 (b)    Disconnect reverse radar probes B006、B009.                                                   04

                                                           (d)    Measure the electrical resistance between
                                                                  reverse radar probesB006(4), B009(4)
                                                                  and the ground respectively.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)


                                                            Multimeter connection          Standard value
                                                            B006(4)、B009(4)                      <2Ω
                                                                    - ground









                 Check whether the result is normal?
                 Yes> go to step 4.

                 No > Maintenance or replace harness.

                 4 .    Check harness and connector (reverse radar probe - body control controller)
                 (a)    Ignition Switch: OFF.
                 (b)    Disconnect reverse radar controller C035.
                 (c)    Disconnect reverse radar probe B006.

                                                           (d)    Measure the electrical resistance between
                                                                  reverse radar controller C035(D31)and
                                                                  reverse radar probe B006(1).

                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                                            Multimeter connection          Standard value
                                                              C035(D31) - B006
                                                                                                 <2Ω
                                                                       (1)









                 Check whether the result is normal?
                 Yes> go to step 5.





                                                                                                         Page 713
   708   709   710   711   712   713   714   715   716   717   718