Page 717 - Foton Workshop Manual - Tunland (AT)
P. 717

DIAGNOSTICS - REVERSE RADAR SYSTEM                           04-571

                                                           (e)    Measure the electrical resistance between
                                                                  left reverse radar probe connector B006(1)
                                                                  and reverse radar controller connectorC035
                                                                  (31)
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)            04

                                                            Multimeter connection          Standard value

                                                            C035(31)- B006(1)                    <2Ω









                 Check whether the result is normal or not?
                 Yes>Replacement reverse radar controller.
                 No > Maintenance or replace harness.