Page 726 - Foton Workshop Manual - Tunland (AT)
P. 726

04-580                      DIAGNOSTICS - REVERSE RADAR SYSTEM

           Diagnostic steps

           1 .    Check harness and connector (reverse radar probe-ground)

           (a)    Ignition Switch: OFF.
           (b)    Disconnect left reverse radar probe connector B006.
           (c)    Disconnect right reverse radar probe connector B009.
      04
                                                      (d)    Measure the electrical resistance between
                                                             left reverse radar probe connector B006
                                                             (4)、B009(4) and the ground
                                                             respectively.

                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                                       Multimeter connection          Standard value

                                                         B006(4) - ground
                                                                                           <2Ω
                                                         B009(4) - ground






           Check whether the result is normal?

           Yes> go to step 2
           No > Maintenance or replace harness.

           3 .    Check harness and connector (reverse radar controller-reverse radar probe)

           (a)    Ignition Switch: OFF.
           (b)    Disconnect left reverse radar probe connector B006.
           (c)    Disconnect reverse radar controller connector C035.


                                                      (d)    Measure the electrical resistance between
                                                             left reverse radar probe connector B006(1)
                                                             and reverse radar controller connector C035
                                                             (31).
                                                             Standard electrical resistance (check
                                                             whether there existent an open circuit)

                                                       Multimeter connection          Standard value

                                                         C035(31) - B006                   <2Ω
                                                                (1)







           Check whether the result is normal or not?

           Yes> go to step 3