Page 770 - Foton Workshop Manual - Tunland (AT)
P. 770
04-624 DIAGNOSTICS - POWER WINDOW
(f) Use multimeter to measure the resistance
between stitches A7, A8, A9, A10, A11, A12
of connector C033 of body controller and the
ground.
Standard resistance (check whether there
is short circuit)
04
Multimeter connection Standard value
C032 (A7)- ground < 2 Ω
C032(A8) -ground < 2 Ω
C032 (A9)- ground < 2 Ω
C032 (A10)- ground < 2 Ω
C032 (A12) -ground < 2 Ω
C032 (A11)- ground < 2 Ω
(g) Use multimeter to measure the resistance
between stitches B9 and B10 of connector
C033 of body controller and the ground.
Standard resistance (check whether there
is short circuit)
Multimeter connection Standard value
C033 (B9)- ground < 2 Ω
C033 (B10)- ground < 2 Ω
Check whether the result is normal?
Yes> go to step 7
No> Repair the to-ground circuit from body controller to the power window motor.
7 . Check assembly circuit of power lifter
Page 770