Page 773 - Foton Workshop Manual - Tunland (AT)
P. 773

DIAGNOSTICS - POWER WINDOW                              04-627

                                                           (c)    Use multimeter to measure the resistance
                                                                  between stitch 11 of connector J004 of the
                                                                  power window switch of driver’s door and
                                                                  the ground.
                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)
                                                                                                                     04
                                                            Multimeter connection          Standard value

                                                               C040 (11)- ground                ≤ 2 Ω









                 Check whether the result is normal?
                 Yes> go to step 10.
                 No> Repair the open circuit between stitch 11of connector J004 of power window

                 switch, driver’s door and ground.

                 10 .   Check power window switch, driver’s door

                                                           (a)    Disconnect connector J004 of power window
                                                                  switch, driver’s door.

















































                                                                                                         Page 773