Page 773 - Foton Workshop Manual - Tunland (AT)
P. 773
DIAGNOSTICS - POWER WINDOW 04-627
(c) Use multimeter to measure the resistance
between stitch 11 of connector J004 of the
power window switch of driver’s door and
the ground.
Standard electrical resistance (check
whether there existent an open circuit)
04
Multimeter connection Standard value
C040 (11)- ground ≤ 2 Ω
Check whether the result is normal?
Yes> go to step 10.
No> Repair the open circuit between stitch 11of connector J004 of power window
switch, driver’s door and ground.
10 . Check power window switch, driver’s door
(a) Disconnect connector J004 of power window
switch, driver’s door.
Page 773