04-696                     DIAGNOSTICS - POWER REARVIEW MIRROR

                                                      (e)    Check start and cut-off relay R04
                                                             Standard resistance:

                                                                           Multimeter
                                                        Conditions        connection         Specified
                                                                                                value
                                                                             stitch
      04
                                                           Normal
                                                                              1 - 2          Breakover
                                                          situation
                                                        Apply power
                                                       supply voltage
                                                         to position          3 - 4            Cut-off
                                                       between stitch
                                                          1 and 2,



           Check whether the result is normal?
           Yes> go to step 5.
           No>Replace relay.


           5 .    Check harness and connector (rearview mirror heating relay—rearview mirror
                  asembly)
           (a)    Disconnect battery negative cable.
           (b)    Pull out rearview mirror heating relay R01 inside fuse box of the body.

                                                      (c)    Disconnect left power rearview mirror
                                                             connector J003.
                                                      (d)    Disconnect right power rearview mirror
                                                             connector G002.










                                                      (e)    Measure the electrical resistance based on
                                                             the value in the following form.
                                                             Standard resistance (check whether there
                                                             is short circuit)

                                                       Multimeter connection          Standard value
                   30
                                                          J003(1)-R01(30)                 < 2 Ω
                                                         G002(1)-R01(30)                  < 2 Ω