Page 952 - Foton Workshop Manual - Tunland (AT)
P. 952

04-806                           DIAGNOSTICS - AUDIO SYSTEM

                                                      (b)    Use a multimeter to measure the resistance
                                                             between pin 4 of connector C044 of acoustics
                                                             unit and the ground.
                                                             Standard resistance (check whether there
                                                             is short circuit)

      04                                               Multimeter connection          Standard value

                                                          C044(4) - ground                >1MΩ











           Check whether the result is normal?
           Yes > Go to step 3.
           No > Replace fuse: F22 (7.5A), and repair the to-earth short-circuit of circuit from fuse
           F22 (7.5A) to pin 7 of connector C044 of acoustics unit.


           3 .    Check the acoustics unit module

                                                      (a)    Disconnect the battery negative cable,
                                                             disconnect the connector C044 of the
                                                             acoustics unit.

                                                           NOTICE

                                                      Be careful not to drop the acoustics unit.










































                                                                                                         Page 952
   947   948   949   950   951   952   953   954   955   956   957