DIAGNOSTICS - AUDIO SYSTEM                             04-807

                                                           (b)    Use a multimeter to measure the resistance
                                                                  between pin 7 of connector C044 of acoustics
                                                                  unit and the ground.
                                                                  Standard resistance (check whether there
                                                                  is short circuit)

                                                            Multimeter connection          Standard value            04

                                                                C044(7) - ground                >1MΩ











                 Check whether the result is normal?
                 Yes > Go to step 4.
                 No > Replace fuse: F3 (15A), and repair the to-earth short-circuit of circuit from fuse
                 F3 (15A) to pin 7 of connector C044 of acoustics unit.


                 4 .    Check the power supply and ground circuit of the audio system
                 (a)    Ignition Switch: OFF.

                                                           (b)    Disconnect the connectors C044 of acoustics
                                                                  unit.
                                                                NOTICE

                                                           Be careful not to drop the acoustics unit.

                                                           (c)    Ignition Switch: ON.







































                                                                                                         Page 953