Page 977 - Foton Workshop Manual - Tunland (AT)
P. 977

DIAGNOSTICS - HORN                                 04-831

                                                           (b)    Disconnect connector C035 of BCM control
                                                                  unit.







                                                                                                                     04





                                                 ftwxd041025

                                                           (c)    Disconnect the connector C009 of lock spring.



















                                                           (d)    Measure the electrical resistance based on
                                                                  the value in the following form.

                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)
                                                            Multimeter connection          Standard value

                                                            C035(D5)-C009(3)                     <2Ω
                      C035





                              C009










                                                 ftwxd041383


                 Check whether the result is normal?
                 Yes> Replace BCM control unit.

                 No > Maintenance or replace harness.

                 7 .    Check the harness and connectors (horn relay - horn)





                                                                                                         Page 977
   972   973   974   975   976   977   978   979   980   981   982