Page 979 - Foton Workshop Manual - Tunland (AT)
P. 979

DIAGNOSTICS - HORN                                 04-833

                                                           (c)    Disconnect the connector A018 of bass horn.
                                                           (d)    Disconnect the connector A017 of althorn.







                                                                                                                     04










                                                 ftwx811002


                                                           (e)    Measure the electrical resistance based on
                                                                  the value in the following form.

                                                                  Standard electrical resistance (check
                                                                  whether there existent an open circuit)

                                A018                        Multimeter connection          Standard value
                                                               A018 (2) - ground
                                                                                                < 2 Ω
                                                               A017 (2) - ground







                                                 ftwxd041386

                 Check whether the result is normal?
                 Yes> Replace the horn.

                 No > Maintenance or replace harness.