Page 825 - Foton Workshop Manual - Sauvana
P. 825
START AND CHARGING - BATTERY 18A-25
Below is the use of excel tester of discharge plan detection income cross-references.
Display Zone Determination Treatment
White zone Fully charged Go on using
Green zone Normal Go on using
Additional charge (refer to "Chapter18 Starting &
Yellow zone Undercharge
Charging -Battery, Use And Maintenance")
To be further checked after charging (refer to "Chapter
Red zone Over-discharge
18 Starting & Charging-Battery, Use And Maintenance")
3. Voltage test
The following table is derived using the digital multimeter test table.
Voltage Determination Treatment
Above 12.5V Normal Go on using
Additional charge (refer to "Chapter18 Starting &
11.5 - 12.5V Undercharge
Charging - Battery, Use And Maintenance")
To be further checked after charging (refer to
Over-discharge or
Below 11.5 V "Chapter 18 Starting & Charging - Battery, Use And
internal failure 18A
Maintenance")
Page 825