Page 1300 - Workshop Manual - Tunland (2017)
P. 1300
12-40 FUEL - FUEL RADIATOR
FUEL RADIATOR
REPLACEMENT
12
CAUTION
• Ensure the working site is equipped with fire extinguishers before operating the
fuel system.
• Do not use any spark or flame source during the operation of the fuel system.
1 . Release the fuel pressure. (Refer to "Chapter 12 Fuel - fuel system, precaution")
2 . Screw out the fixing clamp of the fuel
radiator inlet outlet pipe, disconnect the
fuel radiator and the inlet outlet pipe.
3 . Screw out the fuel radiator fixing bolt, and
take down the fuel radiator.